Digital Meter DC 100V 50A Voltmeter Ammeter

preview_player
Показать описание
Digital Meter DC 0 ~100V/50A Voltmeter Ammeter Red Led Display Voltage Current Meter DC 12V 24V Tester With Resistive Shunt
Рекомендации по теме
Комментарии
Автор

Thank you! So many of these videos are less clear or don't apply to my situation. Thanks again.

snjsilvan
Автор

ufff eres la solucion que andaba buscando

tincher
Автор

Done it works in bike battery charging and discharging function at a same time its shows reading in negative

TERMINATOR_.
Автор

very well sir thanQ.
but in the 2nd diagram with charger charging current it showing.for the change just replace the charger with the bulb load, without changing any other connections, is the meter shows the discharging current? have u tried.if u tried tell m e sir.because it saves my time.

vsrao
Автор

Hello. I got the same meter on ebay. I connected everything like the video for a 24v power wheel ride on car. After about 10 mins of riding. The shunt got really hot. I touch it and it was very hot can not hold on or will get burn. Is it supposed to get this hot? I'm worried it will damage the power wheel car or catch on fire.

johnrambo
Автор

I have Got This (100V - 10A) Meter and i have found that 2 Adapters was written 9V and Coming 17V :D and another 13.3V and coming 6.5V.

Now About Meter:
You Can Use Meter Only With AC Adaptor Or Battery - To Turn on. Use Minimum 3V Maximum 12V and Maximum 1.5A. Use thin red (+) and thin black (-).

thick Red - is changing Pulses
thin Yellow - also changing Pulses
thick Black - also changing Pulses

1) Volt measures thin Yellow and thick Black
2) Volt measures thin Yellow and thick Red
3) Amps measures thick Red and thick Black

NatishHD
Автор

The one I have is giving wrong ammeter readings and the trim pot at the back is doing nothing. Is it faulty? I have the same connections.

dhruvbose
Автор

Do you know if we mast use Fuse?If yes how many amperes?

antonis
Автор

does your digital Volt/Amp meter has an internal shunt in it's pcb board? I have two digital meters, one has an internal shunt and the other dont. Which one did you use? Thanks.

joelmendoza
Автор

Can i Kill the power to save Energy and still let flow electricity through the wires

googlekonto
Автор

So we need a two batt?what if i use in motorcycle?

akolngto
Автор

What happens if we (mistakenly) reverse the direction of the Ammeter connections on the shunt (I.e.we let the current flow in the opposite direction of the ammeter)?

anassyria
Автор

To use an external shunt, do I need to remove the small shunt installed on the meter?

sledzeppelin
Автор

If used to measure the current of the inverter Which circuit must be connected?

yygprlj
Автор

How it shoes accurate amp through the shunt?? ... I have tried this connecting method... Shows an amp drop through the shunt.. Tried calibrating through the trimmer... Still in accurate..

abzaman
Автор

Bro ye metter alternator charging ke ampere batata hai kya

Priyanka_Chouhan
Автор

Ye volt amp meter kaha milega .
Shunt ke sath hoga kya

mangeshkoyande
Автор

Nice video SIR ask ko Lang poh Kung ok Lang ba na kahit wlang load eh may reading ung Amper na 0.70???

luisilan
Автор

Bang klo power of meternya saya colokin ke aki 12 v gpp kn? Jdi cukup pke 1 aki, gx prlu baterai lg

ubayartdesign
Автор

apakah harus pakai 2 power suplai gan?

kgsebin