Deye Inverter - Generator How To Setup Guide

preview_player
Показать описание
Deye is rapidly becoming the market leader in the world when it comes to innovative, reliable and sustainable electronic technology. #deye proudly produce a range of Hybrid inverters, unparalleled in excellence, performance and functionality.

Please Like this video and subscribe to "Tradestep Energy Solutions":
It helps me grow this channel so I can bring you more informative videos like this one.
#solarpower

Also check out the Deye 50kW Hybrid Inverter:

Leave a comment below if you would like to know more about Deye products, how they work and where to find them
Рекомендации по теме
Комментарии
Автор

if I connect Deye 800W grid inverter to the Gen port, does it charge in the day time with the main solar PV panels together? Or do I just connect it to the load side? this will not be fully used if the main PV generates enough power, then it will feed into the grid.

dongsookim
Автор

there a problems running 3 phase generator smoothly and syncron !!! when household loads are on i isle modus is dramatic unbalance on L1, L2, L3 and FUSES fall down. (case why i need a generator!, when grid is off!!! )

AS-dojd
Автор

How does the Deye inverter communicate with the generator? Or does the generator need to be turned on/off manually? Also can one use a petrol generator with a pure sine wave inverter?

antonemilit
Автор

Hello. How to set up the inverter so that it starts the generator only when there is no external electricity (Grid Off), and when the battery is down to 30%, I don’t need to turn it off when it’s charged to 90%, I don’t need time of use!

GYura
Автор

Great video 👌🏻

But did you try it with Battery voltage mode?
It turns on the generator on specific voltage but never turns it off! Can’t find a solution to this.

JosephELKHOURY
Автор

It is strange that wiring for 3 phase generators in parallel are done as each phase goes only to one generator ? Is it correct ? And if this is a right wiring, why it is so ?

maksympereguda
Автор

3KW generator with surge loads. Deye disconnects the generator instead of applying peak shaving and supplying the needed power from the inverter!
It's a problem because the power goes out for a moment and this starts a second pump on the circuit each time pump 1 starts.
I'll have to use a separate less efficient charger or a bigger generator... or more panels, wind turbine, batteries....
Any ideas for settings at the grid input as a generator input, so that it works without hiccups?
Outback did not have this problem and transition from generator to inverter was smoother. It had other problems tho.

Surges really suck, I want soft start for all my motors...

dominus
Автор

I have a 3-phase 12kW inverter.

I used the generator and the main grid through the ATS via the Grid port. Currently, charging happens when the main grid is available, but when the generator is running, charging does not occur. What could be the reason?

saiel_
Автор

I have benzin/gas generator which is simple. What is the best way to connect it to my Deye invertor?

KamenKr
Автор

Please can a three phase generator charge single phase Deye Inverters in parallel

gwanzuwangjonah
Автор

I have 8kw Deye Hybrid inverter Single phase and 25kVA single phase generator. Can i connect my generator to the generator port of deye?. If I connect my generator, can i automate to start it only during brownout?

ENGINEERINGDEPARMENT
Автор

Can we send generater power to grid with this hybrid inverter because my 63 kva generator run by bio gas its almost free fuel

chitranjanswami
Автор

inverter does not detect my generator. what am I missing here?

TheMadFilipino
Автор

Thuis video is not correct the generator dusnt work like this ať all.

arthurvandongen
Автор

Hello. How to set up the inverter so that it starts the generator only when there is no external electricity (Grid Off), and when the battery is down to 30%, I don’t need to turn it off when it’s charged to 90%, I don’t need time of use!

GYura