Denon DN-A200 Amplifier Repair

preview_player
Показать описание
Fault
Amplifier in protection mode.

Initial investigation confirmed that F101 T2.5 Amps as shown in the video had blown indicating a potential short circuit.

Output transistors checked and left channel devices short circuit collector to emitter.

TR517 2SD2083 & TR519 2SB1383 Replaced genuine Sanken originals.

Further checks made no other defective components found.

Bias for each channel set to 10 millivolts Amplifier fully tested working perfectly.