steel details of 30 feet span beam. Rcc reinforcements details of column, beam.

preview_player
Показать описание
,. welcome to civil site knowledge
30 x 40 span beam steell details

Top playlist

1:- सीढ़ी कैसे बनाएं
design of stair

2:- house construction घर कैसे बनाएं

3 :- vastu for house

4 how to calculate quantity of material

5:- घर का नक्शा house plan

6:- आप सभी के comment अनुसार

7:-- basic knowledge for site engineer

8:- Rate analysis

9:- Bar bending schedule ( bbs)

10:- घर बनाते समय ध्यान दें

11:- how to study drawing

12 how to learn auto level


13 :- practical knowledge for site engineer

14:- unit convention

15:- civil engineering knowledge

16: design of beam, footing, column, slab

17:- electric work

18:- how to make a bill

plz subscribe my channel

#civilsiteknowledge

my second channel

D S INFORMATION

plz join

1:- telegram

2:- Facebook group

civil site knowledge

3:- Instagram

FOR BUSINESS INQUIRY

house plan, estimating And costing

Mo. no. 8827398614 ( paid service 6 pm to 9 pm)

thanks for visit
Рекомендации по теме
Комментарии
Автор

Please send next video link of this site

Sudhirpatil
Автор

Sir 16 by 22 house plan ka total saliya detai wala vedio banaye.

pareshprajapati
Автор

30 feet span ke liye sir mene colom 18*10 inch me liya he building g+1 he or bar 4bar 16mm ke or 4 bar 12 mm ke liye ye thik he ya fir koi change kare or 30 feet span beam ka bhi bataye isme kya le

avdheshrawat
Автор

Sir ji kia jiada distance rakhnse future pe kavi Beam pe crack nehi aiga

odiasstory
Автор

Bhai 30 by 60 fit hall desine batao without center column . G+3 12FT flore hight

SachinKumar-qtzz
Автор

Sir can I use 15 ft height coloum 12 mm dia 8 no & 18"&9" size only ground floor and 1st floor roof blue sheet is this ok

kaalaganga
Автор

beam ki width column ki width se kam kyon h? (column 300x500 & beam 350x600)

rpengineers
Автор

Sir, aapka structurul fees kitna hai?

lkj
Автор

Slab beam & plinth beam ka reinforcement share karein

maheshagrawal
Автор

Sir main 2014 Ka paasout hu but mere pass koi experience n hone se Kahi job nahi mil rha h main kya Kru.

purshottamnamdeo
Автор

30 why 70 ka hal hai latak Bheem mein sariya kaun si aur kitni batane ki kripa Karen andar koi colum nahin hai

sundersingh
Автор

How to provide & placement of the steel specially placement of the steel in beams
& provide steel for slab slab

Which will be the 1 way slab and which will be the 2 way slab in this plan?

pritamsinghthakur
Автор

प्रणाम सर
एक घर के नक्शा के बारे मे समझना है । आंगन मे दो कालम के बीच 20.7 दूरी है कालम भी आमने सामने नही और कालम 9×9 का है।क्या करे सर कुछ सुझाव दीजिए।

kartikeyanpandey
Автор

20×20 vastu प्लान के हिसाब से नक्शा बना दो प्लीज + सीडी भी हो डबल स्टोरी ka makan

anilraj
Автор

52 feet *174 feet ka hall banana hai without collum kaise karu

sanjaysoni
Автор

I want to construct 60 feet long beam between 2pillars. How many steel bars should I use, and what size of requisite
between two pillars is 60 feet span possible...?

dubailomiteluguabbai