Introduction to Disconnector or Isolator | Video #5

preview_player
Показать описание
This video explains the purpose of Disconnector or Isolator in a substation! Watch this short but informative video to know briefly about Disconnector or Isolator.
----------------------------
----------------------------
Other videos you may like -
----------------------------
----------------------------

Find me:

Created By : Gaurav J

#Disconnector #Isolator #Substation
Рекомендации по теме
Комментарии
Автор

Sir 3d animations r good and visuals also, putting hardwork thanku sir

balajiprithviraj
Автор

When Isolator operates or Open on On load, it causes high amount of spark which may cause damage to it parts. Absence of Arc quenching medium unable to extinguish/interrupt the arc while operate on load condition. Hence ensure to operate on No load ensuring CB Open. However, Isolator can interrupt of small amount of inductive/capacitive currents to acceptable design limit corresponds to type and voltage class.

SumitKumar-pfgr
Автор

Doing great job about power system thanks alot sir

baqarengr
Автор

Do you in the session of last question answer is
The system will get damaged and interrable

AnilKumar.g
Автор

You are doing a great job Sir. I am preperaing for job interview. I have a question regarding the primary and secondary winding configuration for power transformer used in Step up Substation and step down Substation? Thanks in advance. I have a rough idea, delta-star in step-up and star-delta in step-down.

bilalkakar
Автор

If isolator is operated under on load, it produces heavy spark. Am I right sir

chinnakarlapraveen
Автор

Earth switch is not used for line only .Earth switch is installed in the two ISOLATOR between Breaker and toward breaker side of both isolator

rohiths
Автор

If you open (turn off) a non-load break rated disconnect under load, it may get sparky, smoky, or worse.

sachinkharat
Автор

If we operates isolators while on load then heavy spark will occur and can cause problem for the operators and other devices due to switching without arc quenching medium.

jijovarghese
Автор

Why designate phases R-Y-B? Is this a IEC reference? In North America it is labeled phase A-B-C?

donberg
Автор

Arcing will occur and may damage the contacts of discconector.

youssofasiry
Автор

I wish you’d put closed caption on this video!

joshualynch
Автор

Earth switch operation after opening of Dis-connector switch

nigamsingh
Автор

What happen if we open the disconnect when the current is passing in the line

prameelaejju
Автор

Sir 3d animations r good and visuals also, putting hardwork thanku sir

balajiprithviraj