Per Unit Analysis - how does it work? (with examples) || Basics of Power Systems Analysis

preview_player
Показать описание
Per-Unit analysis is still an essential tool for power systems engineers. This video looks at what per unit analysis is and how it can be used to solve power systems.
0:00 Introduction
2:37 High level intuitive overview
5:11 Step by step description of the method with simple example
13:54 Review of simple example - what can we conclude?
16:27 Dealing with complex impedances and transformers
19:19 Example single phase system
21:20 Dealing with transformers mismatched to our system bases
22:16 Three phase systems with an example
Рекомендации по теме
Комментарии
Автор

The clearest, easiest to understand explanation of per-unit analysis I have experienced after 25 years of experience and learning and 2 degrees in EE done mate !

Rattanhistorybuff
Автор

The best vid on youtube explaining per unit systems, do not expand time elsewhere. gonna share it

MoussaKHALFI-ztkr
Автор

we lack such level of clearity in our educational system. Thanks for clearing the most fundamental concept!

mayurm
Автор

This guy is a genius. Very clear explanation which is very easy to understand

stambulimisamu
Автор

Fantastic! Thank you. I'm taking a power systems class at the moment and was totally lost on per-unit conversions. Your video definitely cleared things up for me. Thank you so much. Very much appreciated.

JosephAMuniz-hmjh
Автор

Thanks for making this topic easy to understand. I have been frustrated by instructors who cannot speak English clearly and don’t know how to explain it.

JohnHickman-cc
Автор

This should have more likes. You do not rush through stuff and assume that the listener is with you. I like that you take the time and give a small example after each statement. It might be a slower pace for a lot of us impatient engineers, but if we actually listen, we can see that all nuances and bases are covered very well.

caleb
Автор

as an EEE engineering student, I can speak for all of us when i say you ARE THE PRECIOUS GEM!!

k-ye
Автор

Very helpful! Very precisely explained! Thanks alot for your time and efforts. Much needed video!

uhameed
Автор

You explained the whole per unit concept in a much more clear and understandable way than my university professor. Great Thanks!

ΓιώργοςΜάριοςΜερκούρης
Автор

Thank you, this is the best video on per unit Ive come across. Keep up the great work

GKASHWINTHAN
Автор

Great explanation of this subject. Watched it a few times and it helped me a lot. Thank you 👍

AK-rjfv
Автор

Well explained thank you very much now I have a full intuitive understanding of per unit systems

humphreyshapi
Автор

My comment is a bit of a side-track, and doesn't involve the 3-phase example at the end of the video. But following along and practicing the technique presented, I'm wondering if some of the examples, if one saw them in the real world, would represent overloads (for the transformers, at least).

At 6:39, the presenter explains that choice of S-base (Sb), the apparent power, can be anything, but good practice says you should choose a value that matches (as closely as possible) the apparent power base of your equipment. With that then in mind…

In the example at 22:48, the math of course all works, but in that result, is it true that the apparent power is 23 MVA, noting the chosen Sb was only 10? Doesn't that mean we've blown out both of the transformers, one of which was rated 8 MVA and the other 12 MVA? If the example represented a real system, wouldn't you need to ensure the apparent power never exceeded 8 MVA, the (I'm assuming) apparent power handling rating of the lower of the two transformers?

I was led to think about this from the prior example showing the nameplate ratings of a transformer at 17:20, which showed it was rated 50 kVA and 3.39%, and the statement following that the percent impedance only makes sense relative to the transformer's base values. Those base values influence your choice of system base (Sb).

In the example at 21:15, both transformers were given as 3% and 5% on 10 MVA, and 10 MVA was chosen as the system base. Working the example, the Ipu came out to 2.31∠-17.1° p.u. (assuming I did it right). This is also 23+ MVA. But we chose 10 MVA as system base, because…somewhere this was a rated limit (came from one or both of the transformers, presumably). It seems like only the first example, at 13:13, had p.u. that were sensible for the apparent power capacity of the system (0.9901 p.u.). The video says that power system engineers recognize that values up to 1 p.u. are immediately recognized as a well behaved system. But in the examples presented in the middle of this video, we get p.u. currents around 2.3, suggesting (if the base values were chosen as the presenter recommends) our analysis has /also/ shown us that these example systems are fubar. Reaction?

atsdroid
Автор

No idea how you get the Ipu in the pu analysis. Can you explain at 16:13

TheSensation
Автор

you are amazing i wish i can watch all the adds here again and again it was really helpful thank you again

danishnaseer
Автор

@16:20 did anyone else get Ipu = 2.39 - j0.275??? Not sure how he gets positive j. Spent the last 20 minutes running it through my calculator and Matlab, and still get a -j. Thanks in advance.

JosephAMuniz-hmjh
Автор

U have saved my semester. What my teacher couldnt explain in an hour was better expalined here in 10min

MrDaniyalAh
Автор

wonderful video about pu in power systems
i have many vids regarding this topic and let me tell you that your vid is the most beneficial vid
thanks a lot

pspmhmd
Автор

Great video but I thought you changed each zone to the new base... ah you covered it... but I also thought you have to be in same voltage base and consider turns ratio

KAFKUBA