Pilot Operated Pressure Reducing Valve - Part 1

preview_player
Показать описание

Follow us for updates every week when we post a new video:

Рекомендации по теме
Комментарии
Автор

At 0:24 we have a 2000 pounds held by a 10 inch area and it gives 200 psi pressure . Then how does the load move in this case when the force is balanced . Should we set the valve a little higher?

sathishr
Автор

Hi, hope you are good. Wanted to know your views on Pressure reducing valves. When I checked, seems that they all have internal leakage through their pilot line. I mean, for a pressure reducing valve to work, the pilot line must drain oil to tank.
So if any pressure reducing valve is connected to an accumulator, it will drain the accumulator till the preset pressure is reached and pilot drain flow will stop !
Am I right? Can pressure reducing valves be used with accumulators? For example, can we have a 3 way pressure reducing valve without internal leakage?
Do we have any models of 3 way pressure reducing valves without leakage?
Does leakage happen when valve is off ?
For e.g suppose I have a 3 way proportional pressure reducing valve; when valve is off, output pressure is zero. If this valve is connected to an accumulator, will it drain all accumulator oil little by little? Will leakage occur when valve is off ?
Thanks.
Kind Regards.

nadeemzzz
Автор

Do U use a check valve with that one or it got it on

dennisparker
Автор

Does this valve relieve the downstream pressure

sathishr
Автор

Please give us solenoid operated relief valve tutorial.

wowseries
Автор

which software you r using to develop these mechanisms

ghfarmsandnurseryambattur
Автор

If preset spring setting of reducing valve is let say 150PSI and a actuator connected at outlet of valve requires pressure more or less than 150PSI to be actuated, then how does reducing valve maitain 150PSI pressure.

pawangundariya
Автор

Can anyone explain why does the outlet piping has a smaller diameter than that of inlet to valve?
Thanks

amrreda
Автор

Does this hold the load if the inlet flow is switched off ?

sathishr
Автор

How many more years should we wait for part 2? 5 years are not enough?)

yxxsjzd
visit shbcf.ru