DLGF: Replacing the sealing band

preview_player
Показать описание
The Festo service2see tutorial is about replacing the sealing band at the linear drive DLGF.

00:00 Parts list: Products and tools
00:13 Demounting the sealing band
02:33 Mounting the sealing band

This video shows the instructions at the following products as an example:
- Linear drive, DLGF-KF-25-200-PPSA, Series M1
- Sealing band, DLGF-G/KF-20...40, Series M2

Festo Service – the channel around the topic service and support. Commissioning, configuring, using and repairing the Festo products easily and quickly. The tutorials of service2see and software2see will support you!

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Further information and helpful links
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Festo Support Portal | Product information and user documentation
- - - -
Festo spare parts catalogue l Spare parts, accessories and dimension
- - - -
Festo online catalogue

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Safety instructions
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
All guidelines, regulations and specifications applicable in the country in which you are located must be complied with before, during and after carrying out this work.
Only qualified specialized personnel who have undergone training and instruction are permitted to install, repair and commission the equipment; such work must be carried out in accordance with the operating instructions for the products concerned. All equipment must always be switched off before commencing maintenance and repair work. All power supplies must be permanently disconnected.
Some protective devices are taken out of operation during maintenance and repair work. They must be properly reinstalled and put back into operation immediately after the work has finished, and their correct functioning must be checked.
Prior to starting work you must read and understand the safety instructions and the instructions for handling the product in full. You must also ensure compliance with these instructions at all times whilst carrying out your work. No liability whatsoever shall be accepted for damage caused by noncompliance. Although every care has been taken when drafting these instructions, Festo SE & Co. KG does not accept any liability for any errors they may contain or the consequences of such errors. Likewise, no liability is accepted for direct or consequential damage resulting from incorrect use of the products and tools.
Should you have any questions or concerns, please contact Festo SE & Co. KG directly. Do not start work until these questions or concerns have been clarified.

#Festo #service2see #dlgf