Hot Gas Bypass Valve Application and Low Load Conditions

preview_player
Показать описание
Hot gas bypass valve operation is utilized in low load applications and conditions. Hot gas bypass puts a false load on the evaporator when the indoor temperature drops off, this helps to prevent short cycling of the compressor in low load applications.

Visit HVAC Know It All on social media Facebook

Instagram

#hotgasbypassvalve #refrigeration #hvac
Рекомендации по теме
Комментарии
Автор

Your explanation was thorough yet simple and to the point. You didn't try to crowd too much information into video.

robertmalone
Автор

i get my gf to run flat after I raise her temp by backing out the screw through an open device, I screw in and out to back tension off, I have some superheat added into that, it gets warmer less chance that will cycle off, and back to normal conditions naturally on its own. I back off again and discharge my load in the theater. the load drops off because the body heat is gone. but I set for that. so that in a nutshell is how I adjust her full capacity attitude and generally a good example of an application of that. happy HVAC guys!

drew
Автор

I see and read most of the comments Most guys understand quick. Others have No clu n got it confused w Txv. U explain it clear. I m not American n clearly understand ....fl weather around 60 s Good time for LAT and Low Load u put an easy Movie Theater example. Tnks n blessings

renecuevas
Автор

I struggle with mechanical load and ambient control. Specifically the applications of Hot Gas bypass and Headmaster Valves. I mostly understand what they do, and why, but i have the damndest time troubleshooting if they are the problem.

Thanks for this video. Long time watcher, seldom commentor.

NotThatGuy_YepThatGuy
Автор

Thanks Gary! Great explanation. Watching this video will make the actual Sporlan literature for these valves easier for me to digest.

chrisnorris
Автор

Thanks so much needed this for tomorrow’s job

mikhaielj
Автор

Good video! It's a way to balance the load on small refrigeration systems

mikefreedom
Автор

Great videos man. Listen to your podcast too. Thank you for what you do for the trade

epicone
Автор

Thanks for the knowledge. I think I’ve learned more from your videos than my coworker who considers himself a “super tech”.

bhunter
Автор

Great explanation on the hot bypass valve. Thxs for the vids!

daviddesilva
Автор

Thank you sir; Great Video keep up the good work

shockiller
Автор

Thank you for sharing your knowledge. Great video

shanegreen
Автор

Good day sir.thanks for information very clear explanation

janeilquino
Автор

We use the same pipe set up but use a rapid cycle solenoid and no HGBV to control really tight temperatures in our environmental rooms.

VapourRose
Автор

great information knowledge is the key to success

neilvestervictor
Автор

So technically its job is similar to a epr and a headmaster ? Great vid and EXPLANATION btw u make it very understanding.

sdsd
Автор

Great demonstration! Thank you very much. What's the purpose of the pressure equalization line here?

mdmuntasiralam
Автор

Have you worked on environmental test chambers and chillers?

johnpolos
Автор

Hi,
Great video !
I have also a hot-gas bypass valve on my LG multisplit, but it is bypassing directly the compressor's output to the input of the accumulator (just before the compressor input).
When the hot-gas is activated, for example when a split is stopped, I can see the high pressure decreasing and the low pressure increasing.
However, what is strange to me, is that when the hot-gas is deactivated after 30 seconds, the high-pressure recovers quite fast its initial value, but the low pressure is dropping much lower than its initial value (for example, from 8.3 bars to 6.7 bars) and seems to stay at this lower value (until the outdoor unit regulation is changing the inverter compressor speed).
Do you have some explanation why it behaves like that ? I am not really sure that it is normal since it is generating periodical fluctuations of the regulation :(
Thanks a lot and regards

chantaledamiengatien
Автор

I have seen some hot gas bypass lines connected to the suction line (in between compressor and evaporator) as opposed to inlet evaporator like in this video. How are they exactly different?

nimbo