Turns Ratio Test (TTR ) of Transformer

preview_player
Показать описание
This video describes the Turns Ratio Test (TTR) of transformer in detail. The procedure for performing TTR test of transformer in delta and star configurations in explained. The analysis/interpretation of the TTR results is carried out.
Рекомендации по теме
Комментарии
Автор

Thank you sir. Your video had 1hr of info jammed packed into 6mins. Truly appreciate it.

cgaasdfasdfasdf
Автор

Your explanation is very very much clear and understandable. I cannot hesitate to subscribe

veneciousmulenga
Автор

Ur videos help me a lot, nice explanation sirr

earnmoney
Автор

I turned on subtitles and everytime you say major faults it corrects the words to farts hahaha
thank you for the videos though i am studying to become an electrician

tyd
Автор

Thanks for your nice explaining


But the equation of erorr I think it well be (actual value - calculate valu) /calculate value*100

sfcgkjk
Автор

TTR test for transformer one of major invergating test transformer with OLTC whenever maintenance on OLTC before and after maintenance on OLTC TTR is performed to compare the result and check the functionility of OLTC up to the mark before put in to services

akhtarhussainshah
Автор

if on result AB/ab it means HV and LV winding both are connected with TTR b/w phsae if AB/an then LV will be divied on sqtr 3

akhtarhussainshah
Автор

Can u explain that in both cases when TTR increases or TTR decreases, cause is same for both that there is shortage or insulation failure on LV or primary side?

engineerkhiyalhussain
Автор

Hello. Which instruments do you recommend with the following specifications

1.BATTERY OPERATED TRANSFORMER RATIO METER PWR1-3B (SPEC; Three phase, battery operated, ratio range from 8 to 2500, fully automated measurement, measuring voltage 10V / 100V selectable, The DISPLAY shows- Ratio, Phase-angle, Excitation Voltage, Magnetising current. 7). Easy to read large LC display for all 3 phases with backlight 8) Built-in printer . 9) A robust case for field use. 


2.PORTABLE OIL DILECTIC STRENGTH TEST SET AUTOMATIC OIL INSULATION TESTER (OTS 60A/80A/100A) with the following spec: 1) fully automatic microprocessor based. 2) Preprogrammed International test standards. 3)Customized test sequences. 4)upgraded sequence as per IEC60156-201. 5) Suitable to test Mineral, Easter and Synthetic Oil. 6) Internal Memory for 100 Test results. 7)USB Interface. 8) Inbuilt Thermal Printer. 9) Voltage checker for onsite Calibration. 10) Bluetooth connectivity via Motware Ap.

thebemonyatsi
Автор

Character In the video It's great, I like it a lot $$

tiennguyen
Автор

When doing TTR test, Does The Transformer have to be in energized state or not? Thank you.

princetrixiebennedict
Автор

in y connection if TTR is connected between two phase ther no need to divied the Y connect side on sqrt 3

akhtarhussainshah
Автор

SIR turns ratio PRIMARY BY SECONDARY OR SECONDARY BY PRIMARY IT IS DIFFERENT IN DIFFERENT BOOKS

shesnsjsb