Top Phase Converter Tips

preview_player
Показать описание
In this video, Chris shares the Top 5 things you should consider before your purchase such as:

-What you need to run a phase converter.
-How to determine the right size phase converter for your load.
-The right phase converter for your type of application.

For more information contact American Rotary at 888-743-6832.

Рекомендации по теме
Комментарии
Автор

I have their product. the best in the industry. I had a phoenix phase converter. it was a piece of junk. American rotary helped me out with great customer support. I run their unit 10 hrs a day 7 days a week

ultramaxracing
Автор

How do you mount these bottom isolation pads the bolts go right though what holds it onto the motor?

jasperjones
Автор

I have a granite bridge saw and is a 3phase I want to know what comverte should I used for that machine?

sixtovargas
Автор

Hi there
I've bought a pizza oven lincat po360-2 it's 14.4kw 400v 3phase what size of converter I need to buy!???

hamzadorukyldrm
Автор

are they ever bolted to the ground or just sit there??

martinmoffitt
Автор

so how are you balancing the run voltages coming out of the converter so that they are say + - 10 % of each other? Are you using a microprocessor to do the switching with run caps or just run caps alone?

perceive
Автор

I have a good question, It the out put a 3 phase of 120 degree or 90 degree? In other words is that covers the hole cycle or just covers 270 degrees out of 360?

behrooz
Автор

i have a 15 hp motor used to drive a hydraulic pump. i suppose a 5 hp would work, but i just happen to have a 15 hp laying around. the rpm is 1750 the amps for low voltage is 39.3. what would u recommend? thanks

jb-iksj
Автор

In regards to #4- Why don't you use a TEFC motor standard? This is a genuine question as I think theres an answer just not sure of it. Thanks

Steve_Just_Steve
Автор

That was a great video. I need to add one of these for a 3HP Pulverizer. The Amperage is 10, so I did the calculations and it looks like a 20 amp circuit will run this. The motor is a multitap voltage, we are going with 220. We Have a 20 amp double pole breaker with #12 wire going out to the box where we want to install this. Any suggestions on products? I need to go to your website and look at options. It will be located outside, but well under cover from moisture on a loading dock.

deej
Автор

Why it must be multiply to 1.6?
Why 1.6?

illuminationtrick
Автор

I’m new to your channel and very interested. Just subscribed.

paultanner
Автор

Do these converters work on multiple earth neutral (M. E. N) electrical systems?

tristanpatterson
Автор

Was looking to run a 5hp 3 phase air compressor but these things are $2700.00 vs just buying a single phase motor for $570.00 a Baldor. These converters are not worth it they cost way to much you might as well have 3 phase ran from the pole it would be cheaper then these things

AdamOutlaw