Ideal logic Boiler Service - Leeds Plumber

preview_player
Показать описание
Boiler Service Leeds. Full strip down Gas Boiler Service on an Ideal Logic Plus. Boiler Service Guiseley , Boiler Service Yeadon , Boiler Service Horsforth
Ideal logic Combi boiler servicing in Guiseley Leeds, always use a gas safe engineers just take case off so first of all we are going to check inside make sure there are no water leaks we are going to remove sump cover and just check the sump they do sometimes crack just where the cover is its a little bit awkward with one hand while holding camera , first we will take fan out just disconnect the fan and take the screw out under the fan, this is the old style fan and its got a nut on it as well, now we are just going to take the burner out, we have removed the four screws now and we just lift the top off and just pulls out nice and easy just going to check all the burner and make sure its all in good condition also check burner seal , now we are going to brush all this out and then we are going to give it a full clean out, so now we are going to pour some warm water down to wash it through , so all the deposits coming out. Put the front of the sump on so we can pour more water down and put it all back in reverse order , so now we are going to put it into service mode and check high and low with flue gas analyser and check its all working safely
Рекомендации по теме
Комментарии
Автор

Thanks mate. New to the gas industry so seeing these videos is a massive help

cianpapazian
Автор

You r the best mate. yr channel is my favourite .I've learnt from you a lot as a newly qualified Gas safe engineer.

Alshamari-xn
Автор

Good video helped me locate the seized pump.

martinhyre
Автор

I really enjoy your vids thank you, I'm a newly qualified.

VisualGenius
Автор

Did one today what a pain in the back side. Extra small brushes needed. 10 ltrs of water to flush burner.

jasonbrooksbank
Автор

very good video .Please tell me how to remove the black cover ( long one) you shifted to right .on the cover it says no lift how you done please

bensupreme
Автор

Something i was looking for n actually found 👍, i always use key words but takes ages to find on here (if)i find it that is :-/ goes into all directions at times😣, Thank you for that ya made it goid, very much appreciated x

dianaallinson
Автор

Is what you done considered to be a strip down service, as i beleived a lot more would be involved. You didnt check or ckean the electrodes etc.

shaikhimi
Автор

Would cleaning the heat exchanger myself be safe, I am fairly mechanical minded, I have check the manifold, as my Logic was making a loud humming from there when the hot water is requested, which lasts 5-10 seconds.

PLuKE
Автор

I have an Ideal logic combined 30 boiler. A previous engineer did say that the model wasn't very good. I had it on one of those government grant schemes. Now Corgi Homecare aren't going to cover the repair I have been advised to have it power flushed.

solitarymaninblack
Автор

Good job but the Condensate trap will get blocked soon and he will charge a call out fee. Should have clean the trap. Easy to do.

ibysplumbingvideos
Автор

Just so non heating engineers watching this. It takes a lot longer than 5 minutes to do what's been done there. I appreciate your video mate but you have to clarify the time taken to do this as consumers always think we're trying to rip them off when we charge for services even if they don't actually say so to your face.

markst
Автор

Would you hover you analyser around the burner seal to check its sealed correctly after ?

maxwebster
Автор

A decent job there mate. How many British gas engineers would do a service like that. !

buxvan
Автор

All valves should be turn clockwise (in addition to the main gas valve) before striping it down or its not relevant?

luizagil
Автор

If you take electrode out and clean it, is the gas seal broken? Do you need to worry about gas leaks if you clean electrodes by taking them out? Thanks!

kashifahmed
Автор

How would you check flue integrity on these ? Other than out outside

markgratton
Автор

Just had a full service done on my Logic combi 30c. when the burner ignites the boiler gives a loud humming noise for about 3 seconds and then runs like normal, changed the gas valve which helped, but noise came back after a couple of days. Any idea what it could be ?

TheDesiBloke
Автор

Do you drain the boiler before doing this? Do you check the expansion vessel pressure when pressurised or with 0 pressure?

andrewrobertson
Автор

Forgot to clean out the condensate trap? All the limescale flushed from the burner will end up in the condensate well.

Sean-sriv