Ruoshui 4090C LCR Meter Review #092

preview_player
Показать описание
The Ruoshui 4090C LCR Meter - A Review - #092

Victor Ruoshui - Makers web site:

See also Tony Albus’s video on this meter:

This meter appears to be similar to the East Tester LCR Meters.

A good selection of test gear and tools here:
Use coupon code LE10 and help support the channel!

Lab equipment
Oscilloscope (Analog) – Hameg HM 307
Oscilloscope (Digital) – Siglent SDS 1104X-E
Function Generator – Siglent SDG 1032X
Signal Generator – Rapid Electronics 85-1200
Spectrum Analyser – Siglent SSA 3021X Plus
Bench Multimeter – East Tester ET3240
LCR Meter – RuoShui 4090C
Рекомендации по теме
Комментарии
Автор

Thanks! Still liking the ET3240 (thinking about buying it) so I appreciate the little "4-wire" ohms comparison you've done in this video. So even though an LCR meter would be a bit too much for this hobbyist, you answered one of my questions about the ET3240. Thanks!

wernervanschie
Автор

Very nice video and good information. I have the East Tester LCR meter which I think is the exact same unit as yours with different color scheme and power button. I liked the demo where you commented on selecting the proper test frequency. Selecting 100 Hz for the smoothing (power Supply) capacitors. I am in the US so I set my test frequency to 120 Hz for smoothing capacitors. I am no expert either and trying to learn new things in electronic testing. One note when you were measuring the 0.1 ohm resistor I did not see you null the lead resistance (REL) on the two probe test leads connected to the DMM. Seems most test lead pairs are 0.2 to 0.4 ohms and by using the REL function I think your DMM would read much closer to the 0.1 ohms without using the 4-wire technique. Also I think your DMM is using DC test voltages for resistors while you had the LCR meter set to 1 kHz. I doubt if that would make any difference in this example but you can set you LCR meter to use DC (0 Hz) by pressing the DCR button for measuring resistors. Again I think you presented a very nice video on the utility of using an LCR meter. Looking forward to new videos from you.

jwrtiger
Автор

After watching this, I purchased the 4091C 100kHz continuous frequency meter. I can write a SCPI program to pull the data. It just happened to be on sale direct from Roushui's Aliexpress store. Thanks from Colorado.

CraigHollabaugh
Автор

Good review. I'm trying to build an ESR meter at the moment, but maybe I should just follow your lead and get one of these.

icd
Автор

Can you check the reading stability of a resistor in the 1k - 10k range? On a high quality meter, this should give a very stable reading. Looking at the readings during your review, there appears to be quite a lot of instability. Possibly using a low quality ADC or they have noise on the measurement circuit PSU rails?

Chris-hyjy
Автор

Still debating to buy something like this or to upgrade my multimeter with one that does decent for capacitance and inductance measurments for capicators and coils in ham radio type applications

mrbambix
Автор

Is it possible to achieve a degradation mechanism for an electrolytic capacitors using an LCR meter by either considering a thermal or voltage overstress. I am aware one can adjust the voltage for the DUT of the LCR meter but is it possible to have the capacitors placed in an oven and measure with the LCR meter continuously. I look forward to your response.

creativebayo
Автор

I have the 4091C on my bench and the inductance measurements are horribly inaccurate. I measured a 1.6H inductor using a Senncore LC53 (measures at 60Hz). The 4091C measures 7.7MH (which is wildly off). Measures caps just fine. Have you had any success measuring large inductors, 1henry +? Thanks.

CraigHollabaugh
Автор

Will these devices work in USA on 120 volts 60hz

dannytownsend
Автор

Where can I download software for this model?

inakia.
Автор

i have a question that i cant find an answer too. i have a bench lcr meter and it has 4 connections for the kelvin clip test leads. the meter's test lead connections are marked Lcur, Lpot and Hcur, Hpot. which two connections does the positive test lead connect to? i cant find which test lead goes to which two terminals anywhere.

nw