filmov
tv
China CD60 Capacitor Factory
Показать описание
CD60 Motor Starting Capacitor Bakelite Case
Feature & Application
1. CD60 Motor Start Capacitor is made according to American ANSI / EIA –463 standard, a new device developed, bakelite case, high class insulating, high strength, uneasy broken and good sealed.
2. The connection types are of dual quick-connect terminal, wire and cable type.
3. The specific type of capacitors with high electrical characteristics are widely used in single phase A.C. motors with rated voltage of 110V-330V and the frequency of 50Hz - 60Hz to get high rotary torque.
4. CD60 Motor Start Capacitor is suitable used in single phase A.C. motors, compressor, etc.
Technical data and specifications
Reference standards American ANSI /EIA -463
Rated capacitance 21µF ~ 1536µF (MFD)
Tolerance 0 ~ +20%
Rated voltage 110VAC ~ 330VAC
Rated frequency 50/60Hz
Surge Voltage between lugs Applying 1.25 times rated voltage for 2 seconds
Surge Voltage between lug and case 2000VAC 10 seconds non-broken down
Load Life
According to the difference working voltage and capacitance;
Alternation 0.5-4 minute turn on 1 time for second, 12500~50000 times.
Dissipation factor tan δ tgδ ≤ 0.10, tgδ ≤ 0.15 (20℃,100Hz)
Climate types -40℃ ~ +65℃
CD60 Motor Starting Capacitor Metal Case
Feature & Application
1. CD60 Motor Start Capacitor are made of by the aluminium foil bar as the poles, alumina as dielectric, mushy state electrolyte and all of devices in one compact unit which can be sealed separately in aluminium case.
2. The connection types are of dual quick-connect terminal, wire and cable type.
3. The specific type of capacitors with high electrical characteristics are widely used in single phase A.C. motors with rated voltage of 110V-330V and the frequency of 50Hz - 60Hz to get high rotary torque.
4. CD60 Motor Start Capacitor is suitable used in single phase A.C. motors, compressor, etc.
Technical data and specifications
Rated capacitance 21µF ~ 1600µF (MFD)
Tolerance 0 ~ +20%
Rated voltage 110VAC ~ 330VAC
Rated frequency 50/60Hz
Surge Voltage between lugs Applying 1.2 times rated voltage for 2 seconds
Surge Voltage between lug and case 2000VAC 10 seconds non-broken down
Load Life
55℃, 110 ~ 165VAC, 1S on, 59S off, 30000 times
55℃, 220 ~ 330VAC, 1S on, 59S off, 15000 times;
Capacitance change rate: ±15% Initial tested value; Dissipation Factor tgδ: ≤0.20
Dissipation factor tan δ tgδ ≤ 0.10, tgδ ≤ 0.15 (20℃,100Hz)
Climate types -40℃ ~ +55℃