In this HVAC service call, we find a condenser short cycling. Join us as we check the refrigerant charge, air flow, and try to find a leak. Josh recommends replacing the system but the customers decides to repair. there will be a part 2 coming soon showing the full repair. watch until the end to see what MAJOR part has to be replaced!

Join this channel to get access to perks:
Рекомендации по теме
Комментарии
Автор

That dirt damn! I had an electrical and electronic hobby growing up and i maintained my Nana's aircon and it was installed in 1990 and replaced 2013. Was once hit by lighting and had to rebuild the controller card. 😂 now its my job

XolaresTiberius
Автор

Super interesting. I bet that pulsating noise is an air pump in the leak detector.

Gersberms
Автор

Hard stars can also add stress to the start winding and potentially decrease the life of the start winding at the cost of a quicker startup that sees less inrush. As always good stuff man

boywhohadatiger
Автор

What is that tablet / app guages your using

randolphpayne
Автор

We had a double start on our outside unit. I would hear the outside unit come on for 5 seconds, then cut off for 5 seconds, then start again and run normally. We tried and looked at everything. Come to find out it was our Nest Learning Thermostat. We got rid of the Nest Thermostat and replaced it with a Honeywell T3.... no issues and it is going on 2 months. I have a Sense power montior, which detected and saw the double start. I showed it to all the techs who was trying to figure out the issue. I highly recommend Sense Power Monitors, they are great at detecting issues that are random.

AlongtheRiverLife
Автор

My AC was installed 11/2023, about 8 months ago. It runs for 8-9 minutes, then turns off for 5-6 during the day...at night, it's the opposite, it runs for 5-6 minutes and stays off for 8-9 minutes...is this normal? I live in Central Florida... I keep the thermostat at 75-76F.

mr.boniato
Автор

The pump on my detector makes that same fluctuating noise when it's in the manual mode. Sounds like the pump is speeding up and slowing down or something. Fieldpiece has still yet to give me an answer whether this is normal or if it is a problem in the circuitry of the detector causing it to do that. But it does seem to work pretty good in the manual mode.
😎👍

sknight
Автор

Thank you for the video. My AC has always short cycled for years now and it's been frustrating because we've had several techs out through my insurance company only to be told nothing is wrong and a check for $75 is written out. Wish I had a friend who can really tell me what's going on with the AC.

BetoTheButcher
Автор

Mine was caused by a defective thermostat.

FarmGalSal
Автор

Here's one thing seems no one on Internet wants to address does cooking at night in summer cause ac not to turn off for hours before going back to normal cycle

woodstockman
Автор

What is the repair that needs to be done on that unit?

Replacement of the coil?

mrsean
Автор

Hey man could you send me a link on what king of blue tooth gauges you have thos look awesome

tommymatthews
Автор

Just repair the leak. It isnt like its full of leaks, besides it is really small leak. It didnt evem had oil on it

carlossandoval
Автор

bruh. u let it short cycle continually. you are damaging their compressor. dude. ITS LOW ON REFIGERANT.

alias
Автор

That condenser unit is too close to wall. I think technician need some room to set and work on unit… maybe I am wrong but that is tight spot at least for me..

chesstime
Автор

The AC runs fine on medium fan speed, but stops after ten minutes on High fan speed. And restarts again after about ten minutes.
Why this peculiar problem?

praveenmalhotra
Автор

That thing is so crammed in the corner, you gotta be a contortionist just to look at the contactor.

HVACGUY
Автор

That is a disgrace how they did not up keep their outside unit! Shameful!

AlongtheRiverLife