EEVblog #1328 - uCurrent OPA189 Measurements

preview_player
Показать описание
Part 3 of designing a better uCurrent series.
Measuring the noise and consumption of the OPA189 compared to the MAX4239 using a dynamic signal analyser and an oscilloscope.

Buy anything through that link and Dave gets a commission at no cost to you.

Donate With Bitcoin & Other Crypto Currencies!

#uCurrent #Design #Measurement
Рекомендации по теме
Комментарии
Автор

05:20 offset & noise amplitudes may wander a bit during the first few minutes after power-on. I've done part-per-billion high-precision frequency measurements [flicker-free at 28 bits in a 32-bit resolution counter] where I need to wait ~ 20 minutes for the reference oscillator to settle down. Patience is a virtue - set up the test, power it on, and head for the coffee machine. Thick wall shielding box wrapped in a bath towel is another virtue, not only for EMI rejection but to add thermal mass. Gotta love these high-resolution measurements - everything is a thermometer if you peer deeply enough into the swamp.

jrb_sland
Автор

Three 20 minute eposiodes means it's the microamp hour!

flymypg
Автор

This is more proof that TI still makes the best parts in the industry, analog or digital. And when TI gives a spec for a product it is a real spec. Not an idealized specification like most other manufacturers give (whenever possible) for their parts.
PS: The in depth looks at this type of thing are great! Thanks for the look at how you do this type of testing.

Dave
Автор

Definitely enjoying the "series" and look forward to more.

innopriest
Автор

Using the uCurrent to measure the power supply current of the uCurrent is a very pleasing recursion, lol

NoOneYouKnow
Автор

Thank you so much. I don't need a lower noise floor uCurrent, but that doesn't keep me from wanting one badly. As soon it's out, I'll upgrade. If they werent so expensive I'ld update one myself just for fun.

Krmpfpks
Автор

You can put stack of two CR2016 instead of one CR2032 and get 6V without changing battery slot.

RomanDvoryadkin
Автор

Sorry that i don't comment all your Videos. I learned so much with your channel 😀. Greetings from Austria 🇦🇹

TheHibener
Автор

the box! (thats EXACTLY what I NEEDED for back in my pirate radio days.. and now I see one 30 years too late! oh, well... )

WarpRadio
Автор

I used the OPA189 in a project recently, it also handles saturation very very well with some input resistors (never tested it without)
at least in my testing of 3 for a few minutes

OneBiOzZ
Автор

Hi Dave, regarding the high frequencies spikes for the OPA189 opamp. If you vary the analyser sampling frequency you could rule out an aliasing effect.

thomascornelissen
Автор

At low frequencies, a steel box will provide much better shielding...

ats
Автор

It's good to enjoy a better performance mod, satisfying.

johnsonlam
Автор

I like this edited videos. Shorter and complete. 👍

lambertax
Автор

Opa is Dutch for grandpa. Seriously love your work Dave big thums

wouter
Автор

What happened to the silkscreen at the bottom right @2:07, Mr. "I vi I L. J n-s" ;)?

AdrianRumpold
Автор

3:28 -> Is that a updated version of the 121GW

Iceteavanill
Автор

Any plans to compare with the ADA4528 that was mentioned in the first video? Would be interesting to see how it stacks up.

samfedorka
Автор

So Dave, when do you want floating measurements instead of it being ground?

PHamster
Автор

I would have tried to screw the enclosure cover. It might have significantly increased the shielding.

Wistigri