What Causes Motor Overload?

preview_player
Показать описание
In this video, we'll review the causes of motor overload, the differences of electrical and mechanical overload, the devices used in solving motor over-exertion, single phase motors, motor warranty, primary symptoms, nuisance tripping, preventing future overload, finding new motors, overload devices (such as the overload relay and variable frequency drive) and more.

If your motors fail often, are losing a large percentage of efficiency, or are over-exerting themselves constantly, you may find this video useful. We'll guide you through the process of preventing future motor overload and ways to check if your motor is overloading.

Supporting articles:

0:00 Intro
0:59 Mechanical and Electrical Overload
1:49 Signs of Electrical Overload
2:55 How to Identify an Overloaded Motor
3:13 Primary Symptoms
3:40 Nuisance tripping
5:03 Preventing Future Overload
6:11 How to Find an Electric Motor Replacement
6:17 Overload Protection Devices
6:31 Conclusion
Рекомендации по теме
Комментарии
Автор

I have a motor with Furnas relay coil, and H12 heating elements, I always have to reset the relay can't figure the problem and the motor current is in range on the motor data plate.

avisbanks
Автор

My concrete mixer motor has wired noise sir, what do you think come be the cause, is working well but sometimes it gives out some little smoke

dmlmediaug
Автор

Hi.
we are experiencing the current issue.
Motor is on a Soft Starter.
motor name plate 283.0 amps.
The motor is pulling over 10 amps in two phases .
input voltage is phase A= 279, phase B= 281, phase C= 282.
we megged the motor and cables they seems to be fine.
There is not loose connections .
there is no weird noises coming from the motor.
there is no high vibration.
motor spins freely and there is nothing jamming the shaft.
We do not understand why the current is high on two phases only.
What kind of test can tell us what the problem is ???.
Thanks.

shamanking
Автор

I do have trail blazer 2016 I do have a problem with overload electricity they told me to change the alternator I changed it but still now the battery and I change it too but still having and showing overload electric on it now I need to know what I have to check or what part I have to check or replace it plz need your help by the way they check everything but still can't fine the problem

ahmedalyazid
Автор

The VFD has already overload protection for the motor? do we really need an another overload protection device?

markkidtapayan
Автор

I have 1hp water pump now it's overload tripping but winding resistance are normal no body earth, capacitor also normal can you give me a advice what i should do, thanks

kamalpiyasiri
Автор

Hello senior, very much interested and passionate about motors, would you mind taking me