Complete Water Solutions takes a look at what is inside a CEDI Stack or Electronic Deionization. We look at taking apart a stack to see what is inside and what makes up the resin layers, membrane layers and electrical current. CEDI / EDI Water treatment has been around for a long time.

cedi for high-purity, industrial deionized water. The series cedi modules deliver superior performance for laboratory and lower flow process applications, the cedi modules are specifically designed for industrial applications. This is a brief overview of a electrodeionization system presented by Complete Water Solutions. Complete Water Solutions designs the best water treatment and purification systems worldwide. ultrapure water is a term in the semiconductor or pharma industry to emphasize the fact that the water is treated to the highest levels of purity for all contaminant types including: organic and inorganic compounds; dissolved and particulate matter; volatile and non-volatile reactive and inert; hydrophilic and hydrophobic; and dissolved gases
Рекомендации по теме
Комментарии
Автор

Validation Engineer, CQV clean utilities projects. Pretty cool seeing the inside disassembled, really adds to the P&ID.

KevinMcLaughlin-ow
Автор

I don't know what material the 2 electrodes at the top of the plastic plate are without being electrolyzed

quyenluong
Автор

Great video. Thanks you. Not everyone can afford to open the EDI module :). I am a water treatment engineer using EDI for pharmaceutical manufacturing. Very informative.

Dreambelarus
Автор

I want to know how you fix anion and cation in edi. and which type of anion exchange membrane and cation exchange membrane.

Taniamustafa
Автор

I can know the price of a small elementary cell, the production of water treated desalination per minute

ABDELBASTKARBAL
Автор

Do you do the remanufacturing EDI ionpure?

axomatic
Автор

Hi. I would like to ask for any recommendation.. our EDI have 4 stacks. 2 of them is not functioning as the amperage is zero. already changed the rectifiers but no improvement. Is the problem within the internals of the stack? thanks

roniesangalan
Автор

Hi, can you explain about electrolyte flow in this module.

mumtazahmad
Автор

Hello i hope you are well, can you give me the names of the constituent element of CEDI please

PrémicesKasamba
Автор

How I can reset, low air pressure fault on edi plant.

ujjawalrai
Автор

We have packs going bad. Our pH on our water is 8.6-9.0 coming out of our RO. We've had intermittent hard water issues from our softeners switching back.

My question is can the granules inside loaded with magnesium/calcium/iron/etc. be saved? I would think trying to recharge them with an acid recirculation might do the trick.

bigal
Автор

I think anion and cation resin are using inside of module. I want to try manufacturing a prototype CEDI module. Which type resin is used in CEDI modules? OH form or Cl form? Or do you have any advice for usable resin brand and model?

kamilaktemur
Автор

Hello, a good video, if you can make a video for us for a simple amateur-made cell, the materials constituting

abdel
Автор

I thank you for this wonderful explanation, but I have a question.. May I know the amount of voltage and current that works on the EDI system, and is it related to the number of cells or layers of the EDI...

زهيرالبياتي-خه
Автор

Please can you help me i have EDI 700 to much problems can you help me

jwanfouad
Автор

Great video. Thanks for the information.
Can we service EDI ?