In this video we install a duct smoke detector and a duct smoke sensor in a newly installed York Package Unit.

Check out these great tools I use on a daily basis! Use the links…SAVE SOME CASH!

Guide Sensmart PC230 Thermal Camera

Discount code to save 10% : 104H1TFB

TOPTES Combustible Gas Leak Detectors.
4 TO CHOSE FROM!

PT210S
Discount Code: GSYQFS4Z

PT299
Discount Code: 4A3HH88Q

PT199
10% off with code: N83SX3Q6

10% off with code: R98D8JH8

Discount Code: 953OHRKL

Get yourself a HIK Micro B20 Thermal Imaging Camera. Use this Link!

10% off with code: FJDYR4W3

WisePro Tradesman Backpack:

If there are any other tools and products I use in my videos that interest you…just ask! I’ll get you a link!

Support the Channel with a Super Thanks or
CashApp: $JeffsHVACAdventures
Venmo: @JeffsHVACAdventures

Like and Subscribe!

Questions, comments or to just say Hi, email me
Рекомендации по теме
Комментарии
Автор

Some boards like Carrier Comercial RTU's come with a place to connect the detector this is always preferred, but if they don't it is better to break 24 to the control board to cause an immediate shutdown of the blower. This is required in our area.

With ECM motors an isolation relay is also required. besides breaking power to the board you must also break the high voltage to the fan, otherwise the fan will continue to run until it times out.

In our area the duct detector must be sensing after the blower motor, in case the motor were to catch fire. This can be done by mounting the detector before the blower with one tube open to the compartment and the second tube with a hose or pipe connected after the blower compartment. No need for the sampling tubes, the difference in pressure before and after the blower, will cause the detector to sample.

If Interlocking detectors they must all use A SINGLE TRANSFORMER dasy-chaining it from RTU to RTU. If you attempt to use more than one transformer you will blow up boards and transformers

Mount detectors so water won't fall into the plastic housing, this is a common failure point when condensate drips into the detector.

HVAC
Автор

we always add a RTS2-AOS test station. We are never aloud to hook up anything to the panel. EVER. That has to be done by a licensed tech. Sometimes depending on the city we aren't even aloud to install the duct detector itself

SilverandCigars
Автор

Never see the Smokes in the Units up on the roof here, just below the roof in the supply and return ducts. Also we use the Air Products SL-2000's with their FastTubes (pack of three 24" tubes) and just snap together and cut (the plastic tube) to length as necessary...light weight, not conduit style with punched holes.

reedrutkowski
Автор

Thanks for the video! I hate that york sells those units with those terrible filters. Nobody ever remembers to order replacements. And then the coils are super dirty when we come back. Especially if its a resteraunt.

speedycl
Автор

Great job Jeff always learn from your videos

TomLawson
Автор

They are also asking for a condensate safety, float, and it has to be inside the unit.

MariosACandRefrigeration
Автор

All fire alarm thermostat wiring by code has to have a red jacket and plenum rated

paulpatenaude
Автор

Nice video Jeff I am assuming the duct smoke sensor requirement is because the unit for heat is natural gas.

Or the unit uses a2l refrigerent which I don't like at all.

gabrielstern
Автор

While it works fine the way you wired it. Those boards have a duct smoke shutdown set of contacts and the simplicity board will display "ductsmoke shutdown" when they trip, instead of just killing 24v to it.... Just makes it easier when troubleshooting for the next guy.

Side note i hate those York/JC boards. 120 seconds evertome you cycle the unit, so stupid.

Hopefully Bosch gets rid of those eventually.

chap
Автор

What do you charge your customers per hour for a job like this?

JackGore