filmov
tv
OPTIMAL LOCATION OF STATIC VAR COMPENSATOR SVC FOR VOLTAGE STABILITY IMPROVEMENT IN IEEE 57 BUS
Показать описание
DESIGN DETAILS
With the increase in power demand, modern power system networks are being operated under highly stressed conditions. This has resulted into the difficulty in meeting reactive power requirement and maintaining the bus voltage within acceptable limits. Voltage instability in the system occurs in the form of a progressive decay in voltage magnitude at some of the buses. The problems of voltage instability and voltage collapse are the major concerns in the operation of power system. Flexible AC Transmission System (FACTS) device in a power system improves the stability, enhances the voltage stability margin, and reduces the power losses. This Matlab design is based on identification of location of FACTS device in the power system using Genetic Algorithm to find optimal location and rated value of SVC device to minimize the voltage stability index, total power loss, load voltage deviation, cost of generation and cost of FACTS device to improve voltage stability in the power system. The design is tested on IEEE-57 Bus System considering different load percentage with conventional method, without SVC and by applying GA using Matlab 2020a. The simulation video shows the performance of the design with its result graphs/values. We have shown the Matlab program implementation of each function i.e Load Flow Analysis with the corresponding file in the simulation video to make you understand how it works.
REFERENCES
Reference Paper-1: Application of Hybrid PSOGA For Optimal Location of SVC to Improve Voltage Stability of Power System
Author’s Name: R. Kalaivani and V. Kamaraj
Source: IJEEE
Year:2012
Request source code for academic purpose, fill REQUEST FORM below,
You may also contact +91 7904568456 by WhatsApp Chat, for paid services. We are also available on Telegram and Signal.
Visit Our Social Media
With the increase in power demand, modern power system networks are being operated under highly stressed conditions. This has resulted into the difficulty in meeting reactive power requirement and maintaining the bus voltage within acceptable limits. Voltage instability in the system occurs in the form of a progressive decay in voltage magnitude at some of the buses. The problems of voltage instability and voltage collapse are the major concerns in the operation of power system. Flexible AC Transmission System (FACTS) device in a power system improves the stability, enhances the voltage stability margin, and reduces the power losses. This Matlab design is based on identification of location of FACTS device in the power system using Genetic Algorithm to find optimal location and rated value of SVC device to minimize the voltage stability index, total power loss, load voltage deviation, cost of generation and cost of FACTS device to improve voltage stability in the power system. The design is tested on IEEE-57 Bus System considering different load percentage with conventional method, without SVC and by applying GA using Matlab 2020a. The simulation video shows the performance of the design with its result graphs/values. We have shown the Matlab program implementation of each function i.e Load Flow Analysis with the corresponding file in the simulation video to make you understand how it works.
REFERENCES
Reference Paper-1: Application of Hybrid PSOGA For Optimal Location of SVC to Improve Voltage Stability of Power System
Author’s Name: R. Kalaivani and V. Kamaraj
Source: IJEEE
Year:2012
Request source code for academic purpose, fill REQUEST FORM below,
You may also contact +91 7904568456 by WhatsApp Chat, for paid services. We are also available on Telegram and Signal.
Visit Our Social Media