How to Read Structural Drawings (Example Reinforcement Drawing)

preview_player
Показать описание
Example of a typical bar call-up on a reinforcement drawing with an explanation of rebar notation. Reinforcing bar positions:
T1 = Top 1st (outer most) layer
T2 = Top and second layer
B1 = Bottom and 1st (outer most) layer
B2 = Bottom and second layer
NF = Near face
FF = Far face
EF = Each face (Both near and far face)
ABR = Alternative bars reversed
STG = Alternative bars staggered
ALT = Alternatively place
IDH = In drilled holes
LINKS = Bars similar in shape to bar codes 33 or 51 in BS 8666: 2005
U-BARS = Bars similar in shape to bar codes 13 or 21 in BS 8666:2005

Bar designations:
B = Grade B500B or B500C conforming to BS EN 10080 and BS 4449
S = Grade 500 deformed stainless steel bars to BS 10088

#StructuralDrawings #ReinforcementDrawing #SteelFixerDrawings

Design to Eurocodes:
EN 1990 (EC0) - Basis of structural design
Design to Eurocode 1 - EN 1991 (EC1) - Actions on structures
Design to Eurocode 2 - (EN 1992 EC2) - Design of concrete structures including concrete bridges
Design to Eurocode 3 - (EN 1993 EC3) - Design of steel structures including steel bridges
Design to Eurocode 4 - (EN 1994 EC4) - Design of composite steel & concrete structures including composite bridges
Design to Eurocode 7 - (EN 1997 EC7) - Geotechnical design

Рекомендации по теме
Комментарии
Автор

Short and clear than those sermons I watch from different people .🙏🙏

obby
Автор

Not enough info .. it would be good to show us the finished product .. keep them coming

pwsoultrainn
Автор

Thanks for the vid. Which brand is that pen/pencil?

googlewestern
Автор

oh yeah .. thank  you this is very helpful

skythecannonball
Автор

Am very much interested how you are doing.

josephharambe
Автор

can you please do a video on grid lines and referencing?

johnevans
Автор

Could you please define H as " 9 H16-03 T4" . what is the purpose of H instead of B

harmindersingh
Автор

Would be grateull if you can explain the meaning of VP. Also I have noted that there is only BOTTOM and TOP labelled but not specific to B1, B2 and T1 and T2. Also the bars to not reach in the beam zone. On a more practical side, the T1 being at the top, T2 is rarely shown in layout but in practice it is placed first, being under T1 bars. Do you have any notes on T2 bars? I am also looking for notes on dropped slab say at balony usually 100 to 150 mm. lower than the remaining slab.

nicolasmarie
Автор

hi, whats the FF and BB stand for? Thanks for example: T13-125(FF)/(BB)

kyhuang
Автор

Hi there, I am new to steel fixing in Sydney, Australia. Are these the plans that are used on jobs around here? If so I would really like to learn how to read and interpret them

ashie
Автор

"#5 @ 12" what does it mean ?

putuwidhikusumayasa
Автор

thank you for the upload. please make more videos of concrete design with eurocode. like & subscribe.

sulaimansamatar