[CC] DPS Digital Phase Shifter in a Demo Board & Testing with a Hioki CM3286-01

preview_player
Показать описание
Hi guys! In this video I installed a DPS, Digital Phase Shifter on a Do-It-Yourself demo board that I made, and tested it with a Hioki CM3286-01 AC Clamp Power Meter. The DPS is a single-phase to three-phase converter. It allows you to run a 3-phase motor out of the available single-phase power supply. The DPS unit model is an MY-PS-2, rated for 1Hp, 220V 3-phase, which is a match for my 1Hp, 3-phase Meiji induction motor. The objective of installing the DPS on a demo board was for me to have 3-phase voltage available for testing purposes, not necessarily for motor control. The DPS did output 3-phase voltage, but it has certain limitations which I discussed in the video. I provided timestamps for easy navigation to topics/chapters. The DPS device is made in Korea.
If you find this useful, please consider subscribing. Thanks for your support and stay safe!

timestamps
00:29 Function of the DPS
01:00 Simple design no moving parts/switches
01:49 DPS rating must match motor rating
02:00 Retail box and user's manual
02:22 DPS connection on demo board
03:07 Time lapse- making the DPS D.I.Y. demo board
05:02 DPS use for 3-phase motors only
05:26 Q&A note 1- single phase output without motor connected
05:55 Q&A note 2- unbalanced output voltage with motor running but not loaded
06:16 using Hioki CM3286, testing output voltage without motor (open ciircuit)
07:58 using Hioki CM3286, testing output voltage with motor running unloaded
10:01 actual output voltage unbalance, unloaded motor
10:39 using Hioki CM3286, testing output voltage phase sequence
13:12 Pros & Cons, closing thoughts
Рекомендации по теме
Комментарии
Автор

Hi sir, how about the current output of the motor? Tama po ba sa rating while running? Thanks

harryocampo
Автор

Excellent is precisely the information I was looking for, I congratulate you for your work!! Greetings from Mexico

GAMAZ
Автор

Thank you for the video, I have a question for you. With no motor hooked up the DPS outputs single phase, two wires have power going out. When a 3 phase motor is powered on single phase, 2 wires having power to it, the third wire on the motor will output power ( like a motor for a rotary phase converter ). When you checked voltage with the motor running how do you know the DPS was putting out 3 lines of power? Couldn't it still be putting out single phase ( two lines ) and the third line was incoming power from the motor that showed your voltage reading?

KCiowa
Автор

Thank you very much for the information, I thought about buying the equipment to test frequency converters in my laboratory but it will definitely not help me, a great contribution, greetings from Peru

albertgng
Автор

After two years, would you still recommend this unit? I contacted the company through ebay regarding my 1.5 hp motor and they were less than helpful regarding whether this unit would work or not. I was quite disappointed. But I don't want to damage my motor. Thank you.

KW-eipi
Автор

Ram, have you tried other similar products that have less imbalance?

kramerfab
Автор

Hi, thanks for you video...i have one question ? Do you know if this DPS can work with 2 phases 110 volt as in america Dont have one single fase 220 as europ

alexeydearanaespinosa
Автор

great review. I believe that there is only one capacitor placed inside the phase shifter.

vivekkumar-hpyq
Автор

I love how you bend your wires. Some of them may be bent past the maximum bend radius though.

tomsuica
Автор

Hello! Excellent video! Question. Will this Digital Phase Shifter work for an industrial fan application with a 1hp 3-Phase motor? My concern is if the fan blades would provide enough load to balance the voltages across the legs, since they're not balanced when the motor is unloaded. The blade on this fan is about 30 inches diameter. Would you recommend this for a fan application?

bigtimlikewhoa
Автор

As usual to every uploaded videos sir Ram, very informative content to sir! Looking forward to see more videos from your channel 😀

kyruskabamalan
Автор

good morning sir i like how you explain on your demo very clear and i understand good job.

reneacobausa
Автор

Great review. Nice work, I appreciate the detail. Thanks

mystified
Автор

Hello sir is it applicable to PMSM motor 3 phase .38 HP

mkacytchannel
Автор

hi siir! my question is, is it posible to use this device (DPS) for aircon 5TR? thanks for your answere? Godbless

reylyndaggao
Автор

Anyone running a 7.5 hp compressor with this

MrVozka
Автор

Can I use that on forward reverse control And wye delta control?

cartvincentpalaypayon
Автор

can this be used to run a vfd that will run the motor?

adambergmann
Автор

Are both wires on the top of the phase shifter hot wires 120v each or is one a ground wire

BloodCover
Автор

Hello, I have DPS and it does the same as your test shows on the voltage imbalance…. I am disappointed however in my unit… it claims to have excellent start up torque….But it won’t start my machine unless it is in low speeds. It doesnt seem to have good start up torque as claimed. I run a 3 hp motor on a milling machine. I have to start it in low speed 1st and once running then I can turn my variable hand crank to maximum speed. It makes it difficult if I forget to turn it back to low speed before shutting machine off because machine needs to be running to change speeds. My speed change is done via 2 pulleys opening/closing while running only.

earlmiller