Why Did No One Tell Me This Sooner?! Electricians Hack

preview_player
Показать описание
Here’s a simple but effective top tip for securing isolation on a three-phase neutral switch! 🔧 When locking off, position your device over the neutral instead of the centr. This keeps L1, L2, and L3 accessible for an external Earth fault loop impedance test, saving time and frustration. Many electricians make the mistake of blocking access—don’t be one of them! Try this hack and make testing so much easier!

#electricaltesting #earthfault #electricalinstallation
Рекомендации по теме
Комментарии
Автор

Doesn't the locking device have that big hole that leads right down the the screws for easy access during testing?

ssaw
Автор

Little tips like these are what make my day

Turkishfella
Автор

Some Circuit breakers are designed with their fault vent to discharge onto the load side away from the incoming live mains to prevent a flashover. But in practice the mains is often connected to the load side to suit the layout of the cable installation.

wonton
Автор

"Schneider" very good fuse brand, very good 🤣🤣🤣

ADDSKY
Автор

I like how the voltage sense wires for the Shelly meter were properly fused 👍🏻

cts
Автор

I actually have something like this in my work bag (I work in a datacentre). But its much longer, no wider by much long, Fits much the same way as you show here but because its longer, its recessed on both sides and has a hole in the centre so much so that it don't matter how you place it on breakers like this, you can access all of the conductor's all of the time.

I cant for the life of me remember where i got it from, that tells me i took it from work, so i'm willing to bet it came from APC, Emerson Power or Schnider.

MarkSErrorNaut
Автор

If the installation is already live at the start of the assessment then I would do ZE, PFC, supply polarity and phase rotation before safe isolation

cglees
Автор

Who locks out right there except this guy?

tfad
Автор

Please do another vid with a neutral connection block fitted and a 3 pole switch.

In the AM2, do they ask for the L to N PSCC to be done with the main switch locked off.

I don’t know as haven’t ever completed it.

SME_Ste
Автор

Most people aren't affected by this, because they don't put the lock on in the first place. Don't get me wrong, they should, but hey don't.

farab
Автор

Oh yeah, perfect solution ... thanks from spain 😊

JoseHernandez-lnrn
Автор

What about when you are doing your Neutral Integrity Test?

stevegraham
Автор

Except that the live side you're after is on the top so lock position doesn't matter

Froggability
Автор

“Fantastic opportunity” when you are one word away from hitting the number count. 😂

madmushroom
Автор

Surley when you do your pfc you will also need access to the Nutral

BATMANONLINE
Автор

Would really love you guys to come and do some videos here in Spain of some installations!!

You would have at least a daily video for a year of how cowboy it all is!!

Mike-shcb
Автор

Isn't it custom to have neutral on the right side, same as with the breakers?

winch
Автор

Would you have to take the lock off tool off to get the board lid off? Locking off but leaving live terminals open seems pointless to me.

easylikesundaymorning
Автор

You tested load, not line side. You said line conductors.

inthemiddleof
Автор

Earth fault loop impedance? Does that require the live wires?

turboduckhead