Effect of Leading Power Factor | PF Improvement | Lagging vs Leading PF| Hindi

preview_player
Показать описание
Queries Solved:
1. What is power factor.
2. What is lagging power factor.
3. What is leading power factor.
4 Power factor improvement.
5. Lagging pf vs leading pf.
6. What is shunt reactor.

Hello friends in this video we discussed about leading power factor in the simplest way possible.

About channel:
In this channel we cover the topic like, Power system and general electrical in the simplest way possible.

#PowerFactor
#Lagging
#Leading
#ShuntReactor
#ReactivePower
#ActivePower
#ElectricalWithAbhishekJoshi

Kindly subscribe
Thank you.
Рекомендации по теме
Комментарии
Автор

Waah Joshi sahab waah ! Kya gazab crystal clear awaaz hai apki. Aapne bahut hi shandaar samjhaya. Aapka bahut dhanyawad 🙏🙏🙏

amituddeshia
Автор

My doubt is cleared Today after so many days, Tq Abhishek

reddy
Автор

Hello Joshi ji
I m senior executive in Electrical Engineering in jindal
Watching your every video
Its very useful

mukulnainwal
Автор

Self JE Electrical Indian Railways seeing ur videos. Great work keep it up 👍

erenayat
Автор

Excellent. All of your videos are easy to understand. Please share how to connect capacitor bank/shunt reactor with line and what are it's effect according to connection i.e. parallel/series with line..

gouriprasad
Автор

Excellent concept.Thankyou sir.pl keep on up dating our electrical engineering concepts

shahlalkhan
Автор

Hello sir
11kv/440v 63kva transformer no load par kvah ki reading increase
Hone se power factor ki penalty lag rhi h.
No load par kitne kvar ka fix capacitor lgaye
Power factor. 40 se shi ho jaye

hukamsingh
Автор

sir ap ne thek batya but mj yeh janna ha k leading power factor m kisi b supply ka triping ka issue ho sakta hai kya plz tellme

asifmaqbool
Автор

Thank you sir, good technical information

kishorebabupagolu
Автор

Dear sir ek baar Leading PF and Leading Reactive Power me kya relation hota hai please samjhaiye.🙏🙏🙏

amituddeshia
Автор

two gensets synchronising pr run hy but aik gen ka pf 0.9 hy aur second gen ka 0.7 hy kya problem hy

ROHAILLA
Автор

Sir ky Ham 3 phase transformer or 3 phase motor starter mein capacitor Bank use karte hain kya

aniketmishra
Автор

Nice sir
Sir 3 phase system me unbalance load ho to neutral ka load kaise calculate karte h

pradeepsingh-zysq
Автор

Thank u very much sir, for your best explanation

gyanchandsoren
Автор

Sir can you make video on how to calculate economical power factor for power plant because I have seen that every grid connected power plant maintain their own p.f for example some plant maintain 0.93 Lag and some maintain 0.96-0.98 lag however we knows that if we maintain our p.f near unity it will make power flow more smooth so I want to know that at which power factor plant can run most effectively.

makwanavijay
Автор

Capacitor bank off bhi kar sakte hain, APFC panel auto manual main hain vo check kar sakte hain..

sanketshirke
Автор

Dear we are rental generator comapny we have 2.5 mw load and pf 0.45LD what is the solution. Kindly reply

aamiramingujjar
Автор

PLC troubleshooting p video banaye plz.

sheharyarkhan
Автор

Sir can.you arramge to explain p.f with the help.of powerfactor circle diagram

shahlalkhan
Автор

sir jab power facter leading me chalega us time kva md dimand me kya effect padega... plz 🙏 sir replay

ashishswain