NFPA 13 Fire Sprinkler System Design Calculation Light Hazard Part 1 in Urdu

preview_player
Показать описание
This is a fire fighting design tutorial video about NFPA 13 Fire Sprinkler System Design Calculation Light Hazard Part 1/ NFPA 13 Hydraulic Calculations / Light Hazard Sprinkler Design Part-1 in the Urdu/Hindi language. It is basic learning detailed information about the wet fire NFPA 13 sprinkler system design / NFPA 13d sprinkler system. It is also important for Firefighting/MEP technical staff and designers. Here sharing my experience and knowledge that will be helpful to learn & grow for Junior Engineers & Technical staff. If you found anything which is inappropriate then convey it in the comments for my information and rectification in the future.

Related fire fighting tutorial videos for your watching:

1. Fire Sprinkler System Design Calculation | Ordinary Hazard G-1 | NFPA-13 | Part-1
2. Fire Sprinkler System Design Calculation | Ordinary Hazard G-1 | NFPA-13 | Part-2
3. Hydraulic Calculations | Wet Standpipe System | Class-I | NFPA-14
4. Hydraulic Calculations | Wet Standpipe System | Class-II | NFPA-14
5. Hydraulic Calculations | Wet Standpipe System | Class-III | NFPA-14
6. NFPA-13 Pipe Schedule Method Designing
7. NFPA-13 Sprinkler Heads Distribution
8. NFPA-13 Density & Area of Sprinkler Operation
9. NFPA-13 Sprinklers Discharge Characteristics
10. NFPA-13 System Protection Area Limitations
11. NFPA-13 Protection Areas and Maximum Spacing of Sprinklers
12. NFPA-13 Classification of Occupancies
13. NFPA-20 Fire Pump Setting
14. NFAP-20 & NFPA-22 Anti Vortex Plate Assembly
15. Where PRV is required as per Pressure in Firefighting System?
16. Types of fire sprinkler system of fire suppression systems
17. Combined Firefighting System Water Demand
18. Basic Designing of Wet Standpipe Landing Valve System
19. Wet Riser Landing Valve System
20. Testing of Wet Riser Landing Valve System
21. Fire Hose Reel System
22. Testing of Fire Hose Reel System
23. Dry Pipe Fire Sprinkler System
24. Preaction Sprinkler System NFPA13
25. Single Interlock Preaction Sprinkler System
26. Double Interlock Preaction Sprinkler System
27. NFPA-14 Pipe Schedule Method for Standpipe
28. NFPA-14 Flow Rate Requirements for Standpipe & Hose System
29. NFPA-14 Pressure Design Requirements of Standpipe & Hose System
30. NFPA-14 Classes of Standpipe Systems
31. Installation Detail of Fire Hydrant System
32. Hydrostatic Pressure Testing of Firefighting pipes
33. Passive Fire Protection PFP
34. Fire Pump Types, Part-1
35. Fire Pump Types, Part-2
36. Fire Pump Types, Part-3

#TanweerAhmed #firefighting #sprinkler #HydraulicCalculation #fire #nfpa13 #MEP #design #mechanical #engineering

= YOU CAN FOLLOW ME ON SOCIAL MEDIA =
Рекомендации по теме
Комментарии
Автор

If we get sprinkler sprinkler distance 10 ft . Than branch to branch distance come out to 225/10 = 22.5 . Is very high from branch sprinkle to other branch sprinkler.

kunalkamble
Автор

Sir as per NFPA 13 distance between two sprinklers is 14ft as per you
But we are making fire sprinkler system for 34floor building we are keeping distance between two sprinkler is 3mtr less than 14ft
Will you please explain what is right distance ?

ashishindulkar
Автор

One more doubt if actual hydraulic area exceeds the hydraulic area . Is that fine ?

malsitechproject
Автор

Why all data given in FPS system please make video in MKS system.

neerajpandey
Автор

Please provide calculation and selection of jockey pump main pump and sprinkler pump

ashishindulkar
Автор

Hello sir nice video very understanding one. But i have doubt please can you clear it.
Remote area breadth= distance between branch + distance between branch and wall = 16+16+8+5.33 = 45.33 right . Why didn't take 8 sir . Thank you in advance

malsitechproject
Автор

Sir plz tell me the Sara kuch to ap remote area Kay liay Niall rahay Hain to dosray areas Kay liay kaisay Karain gain

najafjaffry
Автор

can u please tell me about the specific sections of NFPA 13, i mean what sections should i need to studty in order to do hydraulic calculation

zahidulislam-qppc
Автор

Very informative videos, you made sir
Thank you.

samratkaran
Автор

Easy understandable and very informative lecture sir.... Love from Nepal❤❤

pragashdas
Автор

64 pendent sprinkler on 1 floor or pump is down comer than what hp pump is required sir or how can we calculate this one.

goutamsharma
Автор

nice, lecture but for us not hindi or what language his using.. need to read sub. but informative. i appreciate it. Thank you for your knowledge

GearsoftsCoPH
Автор

What is the main purpose of pressure/Air vessel in fire protection system ???

salmanakhtar
Автор

As salam alaikum sir
Sir ap videos ki ek list bane fire fighting ke liye jis mein ek fresher ko konsi video pahle dekhni hai phr uske baad konsi is tarike se take koi confusion na ho samjhne mein.

mdgauharali
Автор

Can we connect with storage tank and swimming pool parallel?

nith
Автор

Alhamdollilah Tenweer Ahmad Bhai sb
Apke Vedio dekh kar bahut Knowledge Mila hai
Allah Apko hamesh khush rakhe/ shehatmand rahe

sajidkhan-ilpo
Автор

That was easy to grasp... Can you please guide about In rack system sir?

muhammadasifiqbal
Автор

Very informative video jazakalla sir g

ZakirKhan-vkvx
Автор

You are great sir. i really so much respect you.

mddastgirkhan
Автор

sir Drawing Wrong H . Ya To calculation Wrong H
Wrong H

AUTOCADWALA_