Major Reasons of AC's Compressor Overheating and Tripping Problem Explained in Hindi by Emm Vlogs

preview_player
Показать описание


In this video you will know about Major reasons of compressor overheating and tripping. Watch this complete video, it will be very helpful for everyone..

FOR MORE INFORMATIVE VIDEOS VISIT "Emm Vlogs" CHANNEL

#ACnotcooling #ACtrippingprobleb

ThankYou for Watching
Mandeep Singh
Рекомендации по теме
Комментарии
Автор

Sir apka videos koi normal admi bhi dekhega toh woh AC tecnician aisehi banjayega...great video👍👌

ramnaslai
Автор

Bhai saab thanks ap ki madad se ham ne apna AC ki khud hi service kar li hai. Thank you very much.

majorsandhu
Автор

Aap bahut soft spoken ho, badhiya tareeke se smjhate ho. Thank you brother

BharatDesignServices
Автор

सत नाम वाह गुरु
वीर जी बहुत ही महत्वपूर्ण जानकारी देने के लिए आपका बहुत बहुत धन्यवाद । हमारे डेढ़ टन वोल्ट्स के ऐसी में 35 MFD क केपीसीतर निकला जो खराब था तो उसमें 35 का ही केपीसीतर लगाना सही है या 45 MFD का भी लगा सकते हैं ।

munnalalgupta
Автор

I have never wrote any thing on comments today writing to and liking and subscribing because u save my 18 mins by describing all reason in part on descriptiom thanks

sahil
Автор

Very nice Mera window AC trip ho gya tha mujhe lga k jal gya hai but aapki video dekh k Dil ko tasali mil gyi thanx

jagdevsingh
Автор

Thankyou very much and take care of you and your family sir.🙏🙏

therajveersingh
Автор

Thank you so much sir for such a detailed explanation. God bless you

sainaik
Автор

kudos to you... for the effort you put in .. i have a 1.5 ton voltas initially it had a issue of compressor just starts and stop with ina asec .. then the capacitor has been changed and it was working well. later on the same issue occured with in 10 days. then we changed the capacitor again but still the issue was persisting then the service guy suggested me that issue could be on PCB. so he took for service and said relay has been replaced then after that...same issue persists.. then he suggested that problem is in compressor and he changed that too...then the A.C started well and it was working for 1/2 an hour then we can hear a noise like electric thud inside the indoor and it trips off everything even the MCB switch for the AC and even the MCB switch which has for the AC line itself.. auto trip... once i leave it for some time .. may an hour if i switch it on again it works... i cannot come to a conclusion. please help me in this regard..

kanakasabapathy
Автор

You have shared detailed information about the AC's outdoor unit problems and how to solve them. Good video.

arunavabanerjee
Автор

Thanks sir nice video 🙏
Apne bahot hi badiya 10 tip's bataye jadatar Jo log ac use karte hain unke liye khas karke jo log Naya AC laga rahe hai unke liye yeh 10 tip's janana bahot jaruri hai sir thanks 🙏

sureshsawardekar
Автор

Thanks for sharing so good thoughts and guidance regarding compressor tripping. God bless u. Rathe Rathe

pkjoshi
Автор

Wonderful information, bahut hi shandar kam kar rahe ho Bhai Saab app.

rajg
Автор

Nice thanks for the nice and very detailed explanation

گمنام-لس
Автор

Excellent presentation of the video with a very good narration in simple words!👍👍👌👌
Thanks a lot for this complete technical knowledge!
वाहे गुरु जी आप पर हमेशा अपनी कृपा बनाए रखें!🙏🙏

surendrasrivastava
Автор

1 air in system
2 low gas
3 low voltage input
4 Dirty condencer coil
5 weak capacitor
6 weak compressor capacitor
7 filter drier or capillary tube
8 compressor terminal losses
9 compressor oil
10 high heat load

zeeshankhan-etuz
Автор

People should see this video before buying an AC. Very Good

mathewcharian
Автор

Excellent knowledge and good presentation 👍

amrindersingh_
Автор

नमस्कार ! आपने बहुतही अच्छा समजाया हैं, आपको हमारा आशीर्वाद, अगर आप मुंबई मे रहेते हैं तो हम आपसे एसी सर्व्हिस कॉन्ट्रॅक्ट कर सकते है, धन्यवाद !

satishchavan
Автор

All Reperengi... Successfull...Thanks Bro....

jagatraj