Home Automation: How to use 0.1s-999 hours Digital Time Delay Relay Dual LED Display

preview_player
Показать описание
Learn how to use this dual LED display relay timer to control an AC or DC load.
The time you can set is 1s to 999s, 1 minuet to 999 minuets, 1 hour to 999 hours. This a great home automation project.
DC12V / AC110V-220V Digital Display Time Relay Automation Delay Timer Control Switch Relay Module - DC12V

The best thank you for me is to not to skip ads and Subscribe 🔔 to my channel, like 👍 the video It is greatly appreciated. 🔔 😊.
I will reply to all Subscriber's 🔔 questions. So make sure to Subscribe and enable the bell 🔔.😊

The range is 0-999 seconds, 0-999 minutes and 0-999 hours.

=======Purchase from Affiliated store ====

Jump to different section of video by clicking on the time:
00:00 Start
00:36 Introduction
01:19 Where to purchase it from
04:13 Inside view images
04:28 Wiring explained
6:55 P1-0 Program
08:00 P1-1 Program
08:24 P1-2 Program
09:00 P1-3 Program
09:55 P1-4 Program
10:26 P1-5 Program

Tutorial by Ahmad Shamshiri form Canada
****************************
****************************

Get other projects code and learn Arduino

**** AFFILIATE PROGRAM ****
#robojax #robojax_timer
Рекомендации по теме
Комментарии
Автор

Hello Mr. Shamshiri, this video was very informative! Also, thank you for the tour you gave me at Ontario Tech! I appreciated your attention to detail in your description of the labs available.

samuelscott
Автор

Thank you for this video. Now I can use it ☺️

eshark
Автор

Thanks for the video. I was curious if this has dual polarity like a normal relay? I'm trying to set a motor to auto reverse at a specific time interval. Would I need to use a normal relay in conjunction with this device in order to achieve the outcome?

briano
Автор

Is there any way to Fix the T2 time - so that it is always limited for safety ? Or to remove options? Can this be done using Tx and Rx on the rear ? Could you make a video describing how ?

michaellieberman
Автор

hello hi, what if im not using the powerload at S1 and S0 ? can i connect the Life wire with S1 and Neutral wire with S0 and by using the T wire connection to the load

muhammadfirdaus
Автор

So this relay does not deliver any power from the power supply but only serves to complete a circuit? The 12 volts is only for powering up the module then? Other than the power required, what difference would the 24v have from the 12v?

Hotshotter
Автор

The module can be triggered remotey, for example with a sensor?

DomixEdge
Автор

Can this module be programmed to simply shut off the load after 3hrs?
Thank you .

Enoch-Gnosis
Автор

Thanks for the video. Rally appreciate it.

ultraali
Автор

Hello Mr. Shamshiri, Thanks and regards.

marionardelli
Автор

I only connected the power supply, a button to turn it on and off and a speed regulator even if it runs very slowly because I need more power than speed given by the characteristics of the motor. It's correct? Thank you

TheMaxvobiscum
Автор

Thanks for the video, I have a 24V DC versoin and I am trying to get a 24 volt DC water heater working through one of these and I can set it up, get the power to come on, runs through the P1-5 on / off programme ( on for 5 seconds off for 15 ) but it doesn't put out any power whatsoever, any ideas, I was wondering if the 300watt dump load is too powerful.

GavinFreedomLover
Автор

good video i needed to know how to wire it thanks

alanjones
Автор

hi there, thank you for your demostration. does the P1 -4 can you set the time in minutes instead of seconds? thank you sir

ismaelvella
Автор

Hello

Thanks for the video.

Can you help me on the following:

I have 2 Air-conditioning units which I don't want to have them turn on (takeoff) at the same time as if that happens the main circuit breaker switch trips.

Therefore I need some sort of a delay-On device that receives signals from the two thermostats of the two AC units and then pass them to there assigned magnetic contactors one after the other with a time difference between the two to prevent the units from turning on at the same moment which will lead to MCB tripping. 

Waiting for your valuable answer. 

Regards,

salsal
Автор

Pv & Sv usually used in controllers like temperature controllers. Pv = Process Value (for example temperature measured in the oven). Sv = Set Value (target temperature for the oven).

guyfisher
Автор

I want the timer to have a default setting of 4 second delay then turn on for a long time say 8 hours - I don't need more than one setting - So if I switch the 12 volt power on and off (key switch) then what will be the default setting? Does my question make sense

readyhouse
Автор

Hi I have one exactly the same do I have to only use Dc Power or I can connect on AC, thanks

vedranknezevic
Автор

Also tell us the ics or microcontrollers which are used in the product while product reviews.

rizwanhameed
Автор

I came across videos on youtube that said a time delay relay can be used to "latch" pulsing power by way of a time delay relay set to 2 seconds to "keep a power signal open". That is, until the trigger is removed. The idea is I will use this kind of relay to power a side view camera on my car to send video to my monitor by using the right and left turn signal wires on the turn signal switch. Can this device facilitate a looping effect via the 2 second delay pulse my turn signals get until I move my turn signal to the neutral position?

anthonystrohmayer