Objective: Deploy 1.75” preconnect with V-Split method.
Task Steps
1. FF chooses correct hose at the order of the engine’s officer.
2. FF places the attack section onto the right shoulder, making sure it is balanced.
3. FF steps forward and turns to the left, grabbing bights from the supply section.
4. FF pulls supply section, clearing the hose tray.
5. FF continues stretching the supply section toward the target and around any obstacles, until complete.
6. FF deploys the attack section using the V-split method.
7. FF calls for water, bleeds line, checks for stream quality and appropriate flow, giving the engineer time to set the proper pressure.
Task Steps
1. FF chooses correct hose at the order of the engine’s officer.
2. FF places the attack section onto the right shoulder, making sure it is balanced.
3. FF steps forward and turns to the left, grabbing bights from the supply section.
4. FF pulls supply section, clearing the hose tray.
5. FF continues stretching the supply section toward the target and around any obstacles, until complete.
6. FF deploys the attack section using the V-split method.
7. FF calls for water, bleeds line, checks for stream quality and appropriate flow, giving the engineer time to set the proper pressure.
Pre-connect 1 Triple Layer Load
300 foot preconnect 1-3/4' hose deployment
2.5' pre-connect, loop 4 deployment
Triple Layer Hose Deployment South Trail Fire & Rescue
EO HL Flat Load 1 75 Load
300ft Single Person Minuteman Handline Deployment
HOSE DEPLOYMENT: HOSE BUNDLE 1 3/4'
hose load: Skid load on a wye deployment
400' Minuteman Dead Load Rack and Deployment
Shoulder Deployment With Forward Ganley Lay Video
Hose Deployment - SBFPD
EO HL Flat Load 1 75 DP
How to Deploy and Repack 1-3/4 Bumper Line
Training Deploying 100ft of 1 75 inch Roundabout
Deployment of 1-3/4' Pre-connected Minuteman Load - exterior operations
Supply Side Hose Deployment
3 Point Pull 1 3/4' pre-connected hose line
Hose Load Configurations and Deployment Techniques
Recruit Class 2013-1 Hose Deployment
Quick Water 1 75 fire line CFD
QuickLay Fire Attack - Fire Hose Packs
200' Speedlay 1.75' Attack Hose Rack and Deploy
Stretching the 1.75' Crosslay
Hose Deployment
Комментарии