If you are not a Plumber, you should watch this video! Tricks installing stop valves for Pvc Pipes

preview_player
Показать описание
Hello friends ! Welcome to my next video! When your home's plumbing has problems, you need a valve on the Pvc Pipes to shut off in an emergency! But how to install the valve correctly, in today's video I will guide you How to install a stop valve for Pvc Pipes in the smartest way! Watch the full video to see how I do it! Surely this trick will help you a lot in the process of repairing Pvc Pipes right here!
Thanks for watching!
#pvc
#pvcpipes
#tricksandtips
#dailytricks
#plumbing
#ideas
Рекомендации по теме
Комментарии
Автор

How to install stop valve on pvc pipes as shown in the video will make the process of replacement or repair later easy and flexible! How do you see the idea of ​​installing the valve on this pvc pipes ? Please leave your thoughts in this comment section! Thanks for watching !

dailytricks
Автор

Correct idea but costly. Single Union can be sufficient

waqarshah
Автор

Here in the US, if I was concerned about easy valve replacement, I would just use a Sharkbite valve. Otherwise, if replacement was necessary, I would just cut out a section of pipe and use cemented PVC couplers to connect a short stub on either side.

lonniemcclure
Автор

You're right about one thing I'm a plumber and I shouldn't have watched this😂😂😂

TimWood-vnpm
Автор

I'm Electronic and Electri Service Engineer . But ❓ I Like The Plumbing Work. Some Time I Fittings Water Pumps Plumber Works. Today I Got New Ideas. Once Again Thank You For Sharing..

eissamuhammad
Автор

nice. The advantage of this method is when it comes to change the ball valve..it makes it easier 👍

shantovinod
Автор

Most expensive valve installation ever!!! Why not just the valve???all you would need is one sch80 socket ball valve!!!

jasonthompson
Автор

I've been brainstorming how to install a 1 inch ball valve into a gravity fed pvc line from my spring fed water tank where it enters the house upstream from my water filter. No flex in the pipe so your suggestion is perfect! Plus, the valve is serviceable in the future without cutting remaining pvc again and again. Thanks!

RetiredHRGuy
Автор

Very informative video. I learned a lot from this one, and the plumber never said a word. His work did the talking. My hat's off to you sir.

fatgirl
Автор

That is the way I assembled my 160' deep well pipe, sans valve, but with couplers between each 20' section of pipe. Continuous poly is usually used but pulling the pump was a lot easier with the couplers when you don't have a crane and winch. Your technique (with one coupler as noted below) is a useful approach to replacing or adding a valve.

schsch
Автор

You only need one disconnect coupling, this is because once the coupling is un-threaded, the valve can simple turn to spin off the male connection on the other side.

quicksilver
Автор

thank you so much, watching from Alaminos city Pangasinan Ph.

rml.
Автор

The correct technique and method is FIP brass 3/4 by MIP male schedule 80 PVC nipple and glue and coupling on the other side of the pipe end of story

asgplumbing
Автор

2 things u forgot . when u cut the pipe u have to deburr it. And second thing u have to clean it with a PVC Cleaner before u get the glue on. These are two very important things.

martink.dronemovies
Автор

Gosh ! Just to fix a $10 valve you have spent twice as much. I would straight away cut the pipe and joined with a pair of joints

techdruid
Автор

The idea is not from a good plumber. Leaks can come from several points aside from being expensive.

chitocajucom
Автор

Mistaken installation of union union must gap around 10 cm. From the valve if pipe have more distance.

dinomanungay
Автор

I am a plumber and still watch this video ❤

Plumberry_Plumbing
Автор

Using conduit for water pipe looks like problem number one.

chadcleary
Автор

Now u have 2 find where they sell it and name of it. Also 2 much thread tape can easily cross thread it when screwing on.