How to Calculate Steel Bars Size and Quantity of Column for House Construction,,, Tutorial (Part 2)

preview_player
Показать описание
#construction #Philippines #column #steelbar

The tie shall be so arranged that every corner and the alternate longitudinal bar shall have lateral support provided by the corner of the tie having an inclined angel of not more than 235° degrees and no bar shall be further apart than 15 centimeters clear on their side from such laterally supported bars."

The size and number of the steel bars to be placed in a tied column is also governed by proportion of its cross sectional area to the gross area of the column.

The cross sectional area of the vertical reinforcement shall not be less than .01 nor more than .09 times the gross area of the column section.
Рекомендации по теме
Комментарии
Автор

goodday sir, newbie in ur channel.ganda po ng explaination nyo very informative n clear rather than the other vlogger na contractor din sa inyo po step by step and malinaw kc sa white board gamit nyo., , continue n keep up d good work i hope na maraming aspiring viewer jan na nagpapatayo at nagbabalak magpagawa ng bahay at bakod nila...cheers

jeglacno
Автор

Hinde basta basta nag dedesign ng column at footing, kailangan malaman natin yung soil bearing capacity, hinde lahat ng bahay parepareho ang size ng column at footing. hinde natin nalalaman ang capacity ng soil para dalhin nya ang load na ilalagay sa kanya. kaya meron meron tayong tinatawag na soil test. pero kung nagtitipid pwede na yang hula lang

manueldomino
Автор

Sir salamat po sa mga videos nyo, very informative.

saritaocio
Автор

Are you kidding me with your section 50cmx25cm? 50cm is 0.50m and 25cm is 0.25m it's a very huge section.

thinkingmind
Автор

Laki Ng poste boss 16mm pa na kabilya at labing dalawa Ang gagamitin.. laking gasto boss...salamat sa video....

jhuzcelclear
Автор

sabi mo bilisblisan mo dahil madaling malobat cp mo e paulit ulit naman. tagal

philbertgumastin
Автор

Sir tanong ko po nagbabago ba size ng bakal ng poste pagpataas na from first floor pataas? Salamat

rodlansangan
Автор

At least may reference na ACI parang nscp na din yan haha👍

sikkens
Автор

Sir saan nyo po galing ung value between 0.1 at ung 0.9, ano po ung reference nyo po? thanks in advance

dangananelwinjohn
Автор

Sna boss dinetalye muna rin laki nung area sq m. Ng laki nung bahay n my 2nd flr sa video.. Sa .25x.50 n col.or distance to distance n bawat column or gaanu b kalawak ng ganyan kalaking column n span at load n tao sa 2nd.flr

MadaraUchiha-vvqf
Автор

Gud ev sir, ask lng, anu ang standard size ng footing pag window level ang bahay, at standard na sukat ng poste? God bless.

antoniojr.estoquia
Автор

Anu dapat na size ng kabilya ang gamitin, ty.

antoniojr.estoquia
Автор

sir can i ask?? pwede na po ang 30cm x 30cm sa two storey house with roof deck?? para sa sukat ng bahay na 4x10m !! thanks

theroblaxtheriches
Автор

sir, ayos na ayos ang blog mo! may tanong ako sir, ano po ba ang sizes ng bakal? pinakamalaki hanggang pinakamaliit.

razelpielago
Автор

sir paexplain po nung .7854 paano nkuha sa compute..? thank po

papabhongtv
Автор

paano standard spacing ng rafters at purlins engr

loidacardona
Автор

sir paano kong matubig ang ilalim nang lupa, ano bang dapat gawin para matibay ang posti nang bahay bali bonggalow type salamat sir.

waltercecilioredulla
Автор

Over quantity na yon 16mm dia dapat ay 6 nos lng kung 2 or 3 storey lng

tab
Автор

Boss, advise lang saiyo...pagdating sa mga Calculation ng Steel Reinforcement, sizes at concrete mix...maling mali iyang ginagawa mo....itigil mo iyan dahil pwede kang mademanda sa ginagawa mong iyan. Pwede vlog mo nalang iyong pag-actual implementation on site sa mga project na nagagawa mo na may plano. Trabaho iyan ng isang Licence Engr, Structural Engr or Architect

constructionstandards-engi
Автор

sir pa video nmn po para SA bega na 30x80x10meters salamt po!

bhecvlog