Why Does My Air Conditioner Circuit Breaker Keep Tripping?

preview_player
Показать описание
Have you had an issue with your air conditioner lately where the circuit breaker at the main panel keeps tripping? Have you gone over to the side of the house and tried to flip that breaker back on only to have it flip right back off? The trip switch in the electrical panel is a safety switch that prevents damage to your home or business. Also called a residual current device, a high current event will trip the electrical breaker and cause you AC not to work. If there is a blown fuse near the condenser that can also warn you of a major electrical event that is occurring at the air conditioner. Kill switch, cutout, trip switch are other words for a circuit breaker too. In this video, I wanted to tell you what could be going wrong with your AC system when this happens.

Call or text us at (916) 877-1577 to schedule an appointment.

=============================================
→ Disclaimer
Portions of stock footage of products was gathered from multiple sources including, manufactures, fellow creators and various other sources. HousecallPro compensates Fox Family should you like what you see in your free demo and sign up with them for 30 days.
Рекомендации по теме
Комментарии
Автор

85 in the house isn't cool, but your video is. Thank you !!!

cjohnson
Автор

Very good. Thank you. I am a licensed hvac tech and glad to see you put out this video.

ramchillarege
Автор

"It takes a licensed contractor to order them from a local distributor"...Well in some areas this is true however one DOES NOT need to be licensed to order HVAC parts other than perhaps refrigerant, online. There are some distributors that voluntarily refuse to sell parts to locals so as to protect their customers, the local yokels that call themselves HVAC techs and the businesses they work for (by the way, plumbing suppliers, electrical suppliers used to do this too) however, it has become a practice that does nothing more than force the consumer away from their business to businesses on the internet that indiscriminately sell to anyone. Frankly, when I moved to Florida 15 years ago I was forced to maintain my own system because of the incompetence of the HVAC techs I dealt with back then having realized that I knew more than they did! I once asked one tech what superheat he measured on my system and he didn't have a clue what I was talking about! Subcooling would clearly be over this guy's head too...

btomas
Автор

my upstairs ac kept tripping after 10min of being on. a handy man had told me to change my air filters first. im a new homeowner so i havent replaced the filters since owning the home..about 2 years. xD. anyway that fixed the problem. dirty filters cause high pressure and make the ac over work so change ur filters every 6 months.

pashapash
Автор

Bryant/Carrier Tripped Breaker Due to Faulty( Contactor) at outside unit, replaced with new part , FIXED THE PROBLEM

chazbOE
Автор

It sounds like you have really good information that I need, but some of us are either deaf or have neurology issue, and we are not able to hear what you're saying. It would had been great adding "CC."

heut
Автор

Solution for compressor and fan drawing more amps install Hard Start

afghvacr
Автор

If the unit has not been cleaned in a while, it may just need cleaning. Make sure the current is off before cleaning. Cleaning is a very simple process. I just paid $260 for a cleaning, when I could have cleaned myself.

CharlesMaryHardy
Автор

What can cause breaker to melt? Condenser motor was changed, contactor, and turbo 200. Original cap was 45/5 and bearings were giving out. So switched out.

Mr_GreenLungs_TXMade
Автор

When you say wiring problem do you mean the house wires or the AC wires?

gladysmendes
Автор

Hahahaha “Not cool”. Good one hahaha. Thank you for sharing sir. This is really good info.

ggua
Автор

Thanks, I have a brand new "ox box" hp, just dis a change out and the compressor will run, but I get no cold or hot suction line.. seems like it's stuck in the center which is rare especially brand new.. curious what you think

ronkirkham
Автор

Just checked with an heat detector that I got from an Ex-csis worker who used to come to visit an elderly person in my building an the areas around the circuit breaker was coming up blood red around the breaker unit…so it’s possible that it’s an electrical issue in my building…ie. possibly an bad circuit breaker …..

chriscjongeneelen
Автор

Its about 92 in my house right now... tried to ask multiple "friends" and not only getting no input.... I'm not even gettin a response! FINALLY. i decide. I'll try to figure this out and/or what i should do via YouTube and simply asking The Lord for guidance.... and little by little I'm now figuring some things out!

coffeeblack
Автор

Mine trips immediately. Could that be the capacitor or the contactor? Hoping it is not the compressor.

blaster-zyxx
Автор

Can you recommend a good AC guy in Northern NJ?

AnnetteHollander
Автор

Our ac is tripping our breaker 1week have past and it's still the same, ac works on fan setting but when in cold setting it immediately trips. What cause this problem? The electrician came but still the same issue happens he can't fix.

Warguy
Автор

Do these things you talk about also relate to a swamp cooler?

colleensgotcha
Автор

How do you wire size and breaker for air handler

onlyulee
Автор

Good info on the video. Now what if the breaker doesnt trip but by turning off and then on will the AC start working. Happened to me twice this week, AC shuts off no power to control panel (no lights) no humming outside unit, overflow switch good, system dead so I go to the cb box, cycle the ac circuit breaker a min later system is running.I really dont want to call a tech if the system is working for now, might get a tech just like you mention. Any suggestions? Liked and sub.Thanks

jimtalor